Buell 2002 P3 Service Manual page 336

Table of Contents

Advertisement

HOME
Is Bank Angle Sensor
Connected?
YES
Disconnect Connector [134].
Measure Voltage On [134B] Between Socket A, LT GN/GY And Socket B, BK
3.0-3.5 VDC
See Next Page
Bank Angle Sensor
Connector [134]
NO
Reconnect.
11-13 VDC
0 VDC
Repair Short
Disconnect Connector [10]. Check Continuity
On LT GN/
Between Socket A, LT GN/GY On Connector [134B]
GY Wire.
And Socket 5, LT GN/GY On Connector [10B].
Continuity Present?
5007
Check Continuity To Ground On TN/Y
Wire, Socket B, Connector [134B].
Is Continuity Present?
Check Continuity To Ground On LT GN/GY
Wire, Socket A, Connector [134B] Or [10B].
Is Continuity Present?
Figure 7-7. Continuous or No Spark At Spark Plug
*
remove Bank Angle Sensor
before disconnecting connector
[134]. Use Harness Connector
Adapter Kit HD-41404,Gray
male probe and patch cord
YES
YES
YES
Repair Short To Ground
On LT GN/GY Wire.
5007
2002 Buell P3: Electrical
To avoid damage to terminals,
NO
Repair Open In
LT GN/GY Wire.
5007
NO
See Starter Interlock
Section 7.11.
5007
NO
Inspect Module Harness For
Damage. Repair If Neces-
sary.
If Harness Is Not Damaged,
Replace Ignition Module.
5009
7-9