Hide thumbs Also See for GT-3 Series:
Table of Contents

Advertisement

3.
Fix the Cap Sensor Holder with the Screw, with tightening torque 1.5 N·m.
4.
Mount the Maintenance Unit. (Refer to "6-1-16. Assembling / Disassembling of the Maintenance Unit". )
5.
Confirm the initial operation, which is OK with no errors occur.
Hint: How to replace with the Maintenance Unit mounted on the printer
Required Tools
・Phillips screwdriver of 70mm long
1.
Turn OFF the printer.
2.
Remove the Screw (2) that fixes the Maintenance Cover (1).
3.
Remove the Screw (4) that fixes the Cap Sensor Holder (3).
(4)
4.
Remove the Connector.
5.
Replace to the new Sensor and connect the Connector. Make sure that the all the claws of the sensor
are properly hooked.
6.
Fix the Cap Sensor Holder (3) with the Screw (4) with tightening torque 1.5 N·m.
7.
Mount the Maintenance Cover (1) with the Screw (2) with tightening torque 0.5 N·m.
(1)
(2)
(3)