Field Service Ver. 2.0 Mar. 2006
9.2.1

X-Rite Calibration (Gradation Adjust)

1. Set up the Service Jig.
2. Call the Service Mode to the screen.
Test pattern
3. Click the X-Rite Calibration key in the
Imaging Process Adjustment screen.
4. Click the Gradation Mode.
4038F2E599DA
5. Check the message that appears,
and then click the Start key in the
External Panel Controller.
6. Test patterns are printed for the four
colors. (Cyan, Magenta, Yellow,
Black)
NOTE
• It will take approximately 2 minutes
for the test patterns to be printed.
C4004P567CA
• During printing, do not open the
front door.
If the front door is opened, restart
the procedure from step 1.
4004D279AA
7. After the test patterns are printed,
check that the message appears,
and then click the Start key in the
External Panel Controller.
C4004P569CA
9. Electrical/Image Adjustment
51