24.3 Fusing Heaters do not Operate

Primary Interlock Switch (S2)
Fusing Unit
Step
Is the power source voltage applied across PJ2PU1-1 to 3
1
on PU1?
During this time, the Right Door should be closed.
Is the power source voltage applied across CN30-1 and 3,
2
or across 2 and 3?

24.4 Power is not Supplied to Option

24.4.1

Optional Paper Feed Cabinet

Step
Is DC24 V being applied to hookup connector CN12-2?
1
Is DC24 V being output from CNCST-2 on PWB-M?
2
Is the fuse on PU1 conducting?
3
24.4.2

Power is not Supplied to Automatic Duplex Unit

Step
1
Is DC24 V being output from CN19-2 on Duplex?
Is DC24 V being output from CNDUP-2 on PWB-M?
2
Is the fuse on PU1 conducting?
3
24.4.3

Finisher

Step
Are DC24 V and DC5 V being applied to CN60-11 and
1
CN60-1, respectively, of the Finisher?
Are DC24 V and DC5 V being applied to PJ6PU1-1 on PU1
2
and CNFIN-1 on PWB-M, respectively?
Is the fuse on PU1 conducting?
3
Relevant Electrical Parts
DC Power Supply (PU1)
Check Item
Check Item
Check Item
Check Item
24. Power supply trouble
Result
Action
Check wiring from power
NO
outlet to S2 to PJ2PU1.
YES
Fusing Unit
NO
Change PU1.
Result
Action
Malfunction in Paper Feed
NO
Cabinet
Check wiring from PWB-M
NO
to CN12 to Paper Feed
Cabinet.
YES
Change PU1.
Malfunction in Paper Feed
NO
Cabinet
Result
Action
NO
Malfunction in Duplex.
Check wiring from PWB-M
NO
to CN19 to Duplex.
YES
Change PU1.
NO
Malfunction in Duplex.
Result
Action
Malfunction in Finisher.
NO
Check wiring from PU1 to
NO
PWB-M to Finisher.
YES
Change PU1.
NO
Malfunction in Finisher.
341