Gradation Reproduction Failure - Konica Minolta magicolor 5430 DL Service Manual

Hide thumbs Also See for magicolor 5430 DL:
Table of Contents

Advertisement

Image Quality Problems
5.1.6

Gradation reproduction failure

A. Typical Faulty Images
B. Troubleshooting Procedure
Step
Section
1
Toner Cartridge Is the outside dirty?
2
PH Unit
AIDC Sensor/Rt,
3
AIDC Sensor/Lt
4
4036fs4048c0
Check Item
Is the window surface dirty?
Is the sensor dirty?
Has the problem been eliminated
through the checks of steps up to
3?
4-38
Main Unit Field Service
4036fs4049c0
Result
Action
YES
Clean.
YES
Clean.
YES
Clean.
Change the Toner Cartridge.
→ Change the PH Unit.
→ Change the AIDC Sensor.
NO
→ Change High Voltage Unit/1.
→ Change High Voltage Unit/2.