Field Service Ver. 2.0 Mar. 2006
25.3.2
Printer Monocolor: white lines in Main Scan Direction, white bands in Main
Scan Direction, colored lines in Main Scan Direction, colored bands in
Main Scan Direction
A. Typical Faulty Images
White lines in Main
Scan Direction
4036fs4025c0
B. Troubleshooting Procedure
Step
Section
Image check
1
Imaging Unit
2
3
4
5
PH Unit
6
7
White bands in Main
Colored lines in Main
Scan Direction
4036fs4026c0
Check Item
A white line or black line in sub
scan direction is sharp.
The surface of the PC Drum is
scratched.
Dirty on the outside.
Contact terminals make good con-
nection between each IU and
machine.
Developing bias contact terminal
makes good connection.
The surface of the PH Window is
dirty.
The problem has been eliminated
through the checks of steps up to 6.
25. Image quality problem
Colored bands in
Scan Direction
Main Scan Direction
4036fs4027c0
Result
NO
Clean the Comb Elec-
trode by moving the Comb
Electrode Cleaning Lever.
YES
Change Imaging Unit.
YES
Clean.
NO
Clean contact terminals.
NO
Clean contact terminal
and check terminal posi-
tion.
YES
Clean with cleaning jig.
NO
Change Imaging Unit.
→ Change Image Transfer
Belt Unit.
→ Change PH Unit.
4036fs4028c0
Action