10. Firmware upgrade
10.3 Firmware rewriting
• The F/W is updated using the Compact flash.
• Do not use the Service Jig or Jig Software for rewriting the F/W.
10.3.1
Updating method
NOTE
• NEVER remove or insert the Compact Flash card with the machine power turned
ON.
[1]
[3]
4. Turn ON the Main Power Switch.
[4]
64
1. Turn OFF the Main Power Switch.
2. Remove the screw [1] and the metal
Blanking Plate [2].
[2]
4038F2C591DA
3. Insert the Compact Flash card into
the slot.
4038F2C592DA
5. The ready to print LED [4] on the
control panel changes its state as
follows: steady light → off → blinking,
and downloading of FW is started.
6. Ready to print LED [4] which is blink-
ing will stay ON when the FW is nor-
mally downloaded.
*It takes about ten minutes until it
stays ON.
4038F2E604DA
Field Service Ver. 2.0 Mar. 2006