16. Image quality problem
16.3.2
Monocolor: white lines in Main Scan Direction, white bands in Main Scan
Direction, colored lines in Main Scan Direction, colored bands in Main
Scan Direction
A. Typical Faulty Images
White lines in Main
Scan Direction
4036fs4025c0
B. Troubleshooting Procedure
Step
Section
Imaging Unit The surface of the PC Drum is
1
scratched.
2
Dirty on the outside.
Contact terminals make good con-
3
nection between each IU and
machine.
Developing bias contact terminal
4
makes good connection.
PH Unit
The surface of the PH Window is
5
dirty.
The problem has been eliminated
6
through the checks of steps up to 6.
216
White bands in Main
Colored lines in Main
Scan Direction
4036fs4026c0
Check Item
Field Service Ver. 1.0 May 2006
Colored bands in Main
Scan Direction
Scan Direction
4036fs4027c0
Result
YES Change Imaging Unit.
YES Clean.
NO
Clean contact terminals.
NO
Clean contact terminal and check ter-
minal position.
YES Clean with cleaning jig.
NO
Change Imaging Unit.
→ Change Transfer Belt.
→ Change PH Unit.
4036fs4028c0
Action