Figure 58 Basic Setting > Stacking > Stacking Status > Slot number
The following table describes the labels in this screen.
Table 37 Basic Setting > Stacking > Stacking Status > Slot number
LABEL
DESCRIPTION
Slot
This field displays the slot ID of the Switch.
Stacking
This field displays whether the Switch is active in the stacking system.
Role
This field displays whether the stacked Switch is a master or linecard Switch
Force Master
This field displays whether the Force Master Mode is enabled or disabled on this Switch. The
Mode
Active Force Master Mode forces this Switch to become a master Switch. This Switch will
have the highest priority over all other Switch in the stack. If two Switches are set as
masters, they will have the same priority level, but the Switch that has the longest active
run-time will be selected as the master Switch automatically.
Priority
This field displays the priority level of the Switch. A higher number represents higher
priority.
Slot ID After
This field displays the slot ID of the Switch after a reboot. You can save the slot ID of the
Reboot
Switch after a reboot by clicking Freeze in the Stacking Configuration screen. See
Section 6.10.3 on page 97
Stacking Status
This field displays whether the stacked Switch is active or inactive in a stack. Init means
the slot ID is initialized by the master Switch.
Master Capable
This field displays whether the Switch has capacity to become a master Switch. Auto
means the stack system master election process will determine if the Switch can be
assigned as a master Switch.
Stacking MAC
This field displays the stacking Switch MAC address.
Address
Stacking
This field displays the status of the port stacking channel 1 of the Switch. It will display up
Channel 1
for active or down for inactive.
Stacking
This field displays the status of the port stacking channel 2 of the Switch. It will display up
Channel 2
for active or down for inactive.
Stacking Up
This field displays the time that the active Switch in a stack has been running.
Time
ZyNOS version
This field displays the ZyNOS firmware that is currently running on the Switch.
*Running/Flash
Chapter 6 Basic Setting
.
GS3700/XGS3700 Series User's Guide