ZyXEL Communications xg3700 series User Manual page 462

Hide thumbs Also See for xg3700 series:
Table of Contents

Advertisement

Table 230 SNMP System Traps (continued)
OPTION
OBJECT LABEL
errdisable
zyErrdisableDetect
zyErrdisableRecovery
dyinggasp
zyHwMonitorDyingGasp
powersourc
zyHwMonitorPowerSourceAbn
e
ormal
zyHwMonitorPowerSourceAbn
ormalRecovered
loginrecord
zyAccessControlLoginRecord
zyAccessControlLogoutRecord 1.3.6.1.4.1.890.1.15.3.9.4.2
zyAccessControlLoginFail
Table 231 SNMP Stacking Traps
OPTION
OBJECT LABEL
Channel
zyStackingChannelUp
zyStackingChannelDown
Slot
zyStackingSlotAttach
zyStackingSlotDetach
Master
zyStackingNewMaster
Upgrade
zyStackingUpgradeFirmwareFai
Firmware
l
Backup
zyStackingNewBackup
zyStackingBackupTakeover
Master
zyStackingNewMasterFromTake
over
Fail
zyStackingSyncConfFail
zyStackingSysRestoreConfFail
zyStackingSlotInitFail
Chapter 48 Access Control
OBJECT ID
1.3.6.1.4.1.890.1.15.3.24.4.1
1.3.6.1.4.1.890.1.15.3.24.4.2
1.3.6.1.4.1.890.1.15.3.26.2.5
1.3.6.1.4.1.890.1.15.3.26.2.10
1.3.6.1.4.1.890.1.15.3.26.2.11
1.3.6.1.4.1.890.1.15.3.9.4.1
1.3.6.1.4.1.890.1.15.3.9.4.3
OBJECT ID
1.3.6.1.4.1.890.1.15.3.9
7.4.1
1.3.6.1.4.1.890.1.15.3.9
7.4.2
1.3.6.1.4.1.890.1.15.3.9
7.4.3
1.3.6.1.4.1.890.1.15.3.9
7.4.4
1.3.6.1.4.1.890.1.15.3.9
7.4.5
1.3.6.1.4.1.890.1.15.3.9
7.4.6
1.3.6.1.4.1.890.1.15.3.9
7.4.7
1.3.6.1.4.1.890.1.15.3.9
7.4.8
1.3.6.1.4.1.890.1.15.3.9
7.4.9
1.3.6.1.4.1.890.1.15.3.9
7.4.10
1.3.6.1.4.1.890.1.15.3.9
7.4.11
1.3.6.1.4.1.890.1.15.3.9
7.4.12
GS3700/XGS3700 Series User's Guide
462
DESCRIPTION
This trap is sent when an error is
detected on a port, such as a loop occurs
or the rate limit for specific control
packets is exceeded.
This trap is sent when the Switch ceases
the action taken on a port, such as
shutting down the port or discarding
packets on the port, after the specified
recovery interval.
The trap is sent when the device power
goes below the normal value.
This trap is sent when the power source
has an error.
This trap is sent when the power source
recovers to a normal status.
This trap is sent when users log in.
This trap is sent when users log out.
This trap is sent when users fail in login.
DESCRIPTION
stacking channel up
stacking channel down
stacking slot attached success
stacking slot detached
backup takeover as master
Upgrade Firmware fail with correspond slot ID.
New Backup with correspond slot ID.
Replaced master with correspond slot ID.
New master from taking over with correspond
slot ID.
Sync. configuration fail with correspond slot ID.
Stacking backup takeover resotre configuration
fail.
Stacking Slot init fail.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs3700 seriesXgs4600 series

Table of Contents