Table 231 SNMP Stacking Traps
OPTION
OBJECT LABEL
Change
zyStackingSlotChangeIndex
zyStackingPriorityChange
zyStackingTopologyChange
Table 232 SNMP InterfaceTraps
OPTION
OBJECT LABEL
linkup
linkUp
linkdown
linkDown
autonegotiation zyPortAutonegotiationFailed
lldp
lldpRemTablesChange
transceiver-
zyTransceiverDdmiTemperature
ddm
OutOfRange
zyTransceiverDdmiTxPowerOutO
fRange
zyTransceiverDdmiRxPowerOutO
fRange
zyTransceiverDdmiVoltageOutOf
Range
zyTransceiverDdmiTxBiasOutOfR
ange
storm-control
zyPortStormControlTrap
Chapter 48 Access Control
OBJECT ID
1.3.6.1.4.1.890.1.15.3.9
7.4.13
1.3.6.1.4.1.890.1.15.3.9
7.4.14
1.3.6.1.4.1.890.1.15.3.9
7.4.15
OBJECT ID
1.3.6.1.6.3.1.1.5.4
1.3.6.1.6.3.1.1.5.3
1.3.6.1.4.1.890.1.15.3.61.3.1
1.0.8802.1.1.2.0.0.1
1.3.6.1.4.1.890.1.15.3.84.3.1
1.3.6.1.4.1.890.1.15.3.84.3.2
1.3.6.1.4.1.890.1.15.3.84.3.3
1.3.6.1.4.1.890.1.15.3.84.3.4
1.3.6.1.4.1.890.1.15.3.84.3.5
1.3.6.1.4.1.890.1.15.3.78.2.1
GS3700/XGS3700 Series User's Guide
463
DESCRIPTION
Stacking change slot index.
Staking prority change.
Staking topology change.
DESCRIPTION
This trap is sent when the Ethernet
link is up.
This trap is sent when the Ethernet
link is down.
This trap is sent when an Ethernet
interface fails to auto-negotiate with
the peer Ethernet interface.
The trap is sent when entries in the
remote database have any updates.
Link Layer Discovery Protocol
(LLDP), defined as IEEE 802.1ab,
enables LAN devices that support
LLDP to exchange their configured
settings. This helps eliminate
configuration mismatch issues.
This trap is sent when the
transceiver temperature is above or
below the normal operating range.
This trap is sent when the
transmitted optical power is above or
below the normal operating range.
This trap is sent when the received
optical power is above or below the
normal operating range.
This trap is sent when the
transceiver supply voltage is above
or below the normal operating
range.
This trap is sent when the
transmitter laser bias current is
above or below the normal operating
range.
This trap is sent when storm control
is detected on a specific port. A
packet filter action has been applied
on the interface.