Sign In
Upload
Manuals
Brands
WAGO Manuals
Control Unit
761-217
WAGO 761-217 Manuals
Manuals and User Guides for WAGO 761-217. We have
1
WAGO 761-217 manual available for free PDF download: Manual
WAGO 761-217 Manual (138 pages)
Telecontrol Module Compact, 8 AI, Web, Telecontrol module for fault detection/indication, monitoring and remote control
Brand:
WAGO
| Category:
Control Unit
| Size: 3.8 MB
Table of Contents
Table of Contents
3
Table of Contents
5
Notes about this Documentation
7
Validity of this Documentation
7
Copyright
7
Symbols
8
Number Notation
10
Font Conventions
10
Table 1: Number Notation
10
Table 2: Font Conventions
10
Important Notes
11
Legal Bases
11
Subject to Changes
11
Personnel Qualification
11
Use of the TO-PASS Telecontrol Modules in Compliance with Underlying Provisions
11
Technical Condition of Specified Devices
11
Disclaimer
12
Firmware Licensing Terms
12
Firmware with Open Source GPL
12
Block Rounding for GPRS Connections
12
Safety Advice (Precautions)
13
Device Description
16
Scope of Delivery
16
Use
16
Table 3: Overview of Functions
17
View
18
Figure 1: Front View
18
Connectors
19
Antenna
19
Figure 2: Antenna Connection
19
Operating Voltage
20
Figure 3: Terminal Assignment for Operating Voltage
20
Table 4: Terminal Assignment for Operating Voltage
20
Grounding
21
Framework Assembly
21
Insulated Assembly
21
Grounding of the TO-PASS
21
Telecontrol Module
21
Table 5: WAGO Ground Wire Terminals
21
Shielding
22
General
22
Bus Lines
22
Signal Lines
22
WAGO Shield Connecting System
23
Figure 4: Example of the WAGO Shield Connecting System
23
Digital Inputs
24
Figure 5: Terminal Assignment for Digital Inputs
24
Table 6: Terminal Assignment for Digital Inputs
24
Counter Inputs
25
Figure 6: Counter Input Pin Assignments
25
Table 7: Counter Input Pin Assignments
25
Analog Inputs
26
Figure 7: Terminal Assignment for Analog Inputs
26
Table 8: Terminal Assignment for Analog Inputs
26
Digital Outputs
28
Figure 8: Terminal Assignment for Digital Outputs
28
Table 9: Terminal Assignment for Digital Outputs
28
Analog Outputs
29
Figure 9: Terminal Assignment for Analog Outputs
29
Table 10: Terminal Assignment for Analog Outputs
29
Serial Interface to the PC and MODBUS Interface
30
Figure 10: Serial Interface to the PC and MODBUS Interface
30
Table 11: Serial Interface to the PC and MODBUS Interface
30
Table 12: PC Interface Cable Assignment
30
Figure 11: MODBUS Communication Diagram
31
Table 13: MODBUS Cable Assignment
31
Display Elements
33
Figure 12: Display Elements
33
Table 14: Display Elements
33
Technical Data
34
Housing
34
Supply
34
GSM Antenna Connection
34
Table 15: Technical Data Housing
34
Table 16: Technical Data Supply
34
Table 17: Technical Data GSM Antenna Connection
34
GSM Communication
35
MODBUS Communication
35
Digital Inputs
35
Counter Inputs
35
Table 18: Technical Data Communication
35
Table 19: Technical Data MODBUS Communication
35
Table 20: Technical Data Digital Inputs
35
Table 21: Technical Data Counter Inputs
35
Analog Inputs
36
Digital Outputs
36
Analog Outputs
36
Data and Event Logger
36
Table 22: Technical Data Analog Inputs
36
Table 23: Technical Data Digital Outputs
36
Table 24: Technical Data Analog Outputs
36
Table 25: Technical Data Data and Event Logger
36
Approvals
37
Standards and Guidelines
37
Mounting
38
Mounting the TO-PASS ® Telecontrol Module to the DIN Rail
38
Figure 13: Mounting the TO-PASS ® Telecontrol Module to the DIN Rail
38
Removing the TO-PASS ® Telecontrol Module from the DIN Rail
39
Figure 14: Removing the TO-PASS ® Telecontrol Module from the DIN Rail
39
Connect Devices
40
Connecting the Push-Wire Connections to the Conductor
40
Connection Examples
41
Digital Inputs
41
Figure 15: Connection Example for Switch at Input DI1
41
Counter Inputs
42
Figure 16: Connecting Example, Switching Contact at Counter Input DI1
42
Analog Inputs
43
Current Measurement
43
Figure 17: Connection Example of Transducer with Current Output at Input AI1
43
Voltage Measurement
44
Figure 18: Connection Example for Voltage Measurement Via U/I Converter at
44
Digital Outputs
45
Figure 19: Connection Example for a Relay at DO1 Output
45
Analog Outputs
46
Current Measurement
46
Figure 20: Connection Example for a Display Device at AO1 Output
46
Voltage Measurement
47
MODBUS Interface
48
MODBUS Coupler/Controller RS-485
49
Figure 21: Connection Example for MODBUS Coupler/Controller RS-485
49
Serial Interface for MODBUS Current Sensor and PC
50
Figure 22: Connection Example for Serial Interface for MODBUS Current Sensor and PC
50
Commissioning
51
Installing the Operating Software
51
Starting the TO-PASS Telecontrol Module
52
Parameterizing
54
General Settings
54
Figure 23: General Settings
54
Table 26: General Settings
54
Reading Parameters from the Module
56
Identity
57
Figure 24: Configuring the Identity
57
Table 27: Configuring the Identity
58
Addresses
59
Figure 25: Configuring the Addresses
59
Table 28: Configuring the Addresses
60
Configuring Inputs and Outputs
62
Digital Inputs
62
Figure 26: Configuring Digital Inputs 1
62
Figure 27: Configuring Digital Inputs 5
63
Table 29: Configuring of Digital Inputs
63
Multiplex Input
66
Multiplex Settings
67
Figure 28: Configuring Multiplex Operation Settings
67
Table 30: Configuring Multiplex Operation Settings
67
Multiplex Alarm Text
68
Figure 29: Configuring Multiplex Operation Alarm Texts
68
Table 31: Configuring Multiplex Operation Alarm Texts
68
Analog Inputs
69
Figure 30: Configuring the Analog Inputs
69
Table 32: Configuring the Analog Inputs
69
Digital Outputs
71
Figure 31: Configuring the Digital Outputs
71
Table 33: Configuring the Digital Outputs
71
Analog Outputs
72
Figure 32: Configuring the Analog Outputs
72
Table 34: Configuring the Analog Outputs
72
Configuring Error Detectors
74
Alarm Messages for Digital Inputs
74
Limit Messages for Counter Inputs
74
Limit Messages for Analog Inputs
74
Acknowledgement
76
Figure 33: : Configuring the Acknowledgment Response
76
Table 35: Configuring the Acknowledgement Response
76
Transmission Repeat Times
77
Figure 34: Configuring the Transmission Repeat Times
77
Table 36: Configuring the Transmission Repeat Times
78
Time Adjustment
80
Figure 35: Setting the Time Adjustment
80
Table 37: Setting the Time Adjustment
80
Modbus
81
MODBUS Settings
82
Figure 36: Configuring the MODBUS Settings
82
Table 38: Configuring the MODBUS Settings
82
MODBUS Alarm
83
Figure 37: Configuring the MODBUS Alarm
83
Table 39: Configuring the MODBUS Alarm
83
MODBUS Registers
84
Figure 38: Configuring the MODBUS Registers
84
Table 40: Configuring the MODBUS Registers
84
Data Logger
85
Figure 39: Configuring the Data Logger
85
Table 41: Configuring the Data Logger
85
Writing Parameters to the Module
86
Operation
87
Remote Query of Process Values
87
Remote Polling Via SMS
88
Table 42: SMS Format
88
Table 43: Items Added to SMS for Counter Inputs
88
Table 44: Counter Status
89
Remote Polling Using the TO-PASS
90
Operating Program
90
Inputs/Outputs
91
Figure 40: Visualization of the Process Values
91
Modbus
92
Figure 41: MODBUS Process Values
92
Counters
93
Figure 42: Counter Process Values
93
Telecontrol
94
Telecontrol Via SMS
95
Setting or Resetting a Digital Output
95
Table 45: Example of Parameters for Set DO
95
Setting an Analog Output
96
Table 46: Example of Parameters for Set AO1
96
Changing the Counter Value or Status
97
Table 47: Control Commands for Counters
97
Telecontrol with the TO-PASS
98
Operator Program
98
Inputs/Outputs
99
Figure 43: Visualization of the Process Values
99
Counters
100
Figure 44: Counter Process Values
100
Acknowledging Error Messages
101
Switching to Standby
102
Displaying the Data Logger (DSP)
103
Table 48: Navigation DSP
103
Displaying the Event Logger (ESP)
105
Diagnostics
106
Test Inputs and Outputs
106
Figure 45: Test Inputs and Outputs
106
Testing the Counter Inputs
107
Figure 46: Testing Counters
107
Testing the Connection
108
Testing the Modem
109
WAGO TO-PASS Web
110
Setting Parameters
110
HTTP Request
111
Example HTTP Request
111
Data Sets
112
Value Script
112
Value Script FW 2.20 (Standard)
113
Table 49: Data Format for Value Script FW 2.20 (Standard)
113
Example of Value Script FW 2.20 (Standard)
114
Value Script FW 2.31 (Extended)
115
Table 50: Data Format for Value Script FW 2.31 (Extended)
115
Table 51: Meaning of Flag
116
Example of Value Script FW 2.31 (Extended)
117
Value Script FW 2.33 (Counter Inputs)
118
Table 52: Counter Status
118
Table 53: Alarm Status
119
Table 54: Signal Quality (from at Reference Guide by Telit)
119
Example of Value Script FW 2.33 (Counter Inputs)
120
Logger Script
121
Logger Script Standard
122
10.3.2.1.1 Binary Data Format for Data Set
122
Table 55: Data Format for Logger Script FW 2.20 (Standard)
122
10.3.2.1.2 Example for Logger Script Standard
123
Logger Script Extension
124
Table 56: Data Format for Logger Script FW 2.31 (Extended)
124
10.3.2.2.1 Data Format for Liox Variable
125
10.3.2.2.2 Data Format for Lpdx Variable
125
Table 57: Data Format for Logger Script FW 2.31 (Extended), Variable Liox
125
Table 58: Data Format for Logger Script FW 2.31 (Extended), Variable Lpdx
125
10.3.2.2.3 Example for Logger Script Extension
126
Logger Script FW 2.33 (Counter Inputs)
128
10.3.2.3.1 Data Format of an Lcdx Variable
128
Table 59: Data Format, Logger Script Extension, Variable Lcdx
128
Table 60: Counter Status
128
Table 61: Number of Data Sets
129
Time Request Script FW 2.33
130
HTTP Response
131
Table 62: Setpoint Settings
131
Example of HTTP Response
132
List of Figures
133
List of Tables
135
Advertisement
Advertisement
Related Products
WAGO 761-216
WAGO 761-214
WAGO 761-210
WAGO WAGO-TO-PASS 761
WAGO 761-111
WAGO 761-112
WAGO 761-316
WAGO 761-110
WAGO 761-314
WAGO 761-114
WAGO Categories
I/O Systems
Control Unit
Power Supply
Switch
Controller
More WAGO Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL