WAGO 761-314 Manuals
Manuals and User Guides for WAGO 761-314. We have
1
WAGO 761-314 manual available for free PDF download: Manual
WAGO 761-314 Manual (98 pages)
TO-PASS Mobile, 4 AI Telecontrol module for fault detection/indication, position monitoring and remote control
Brand:
WAGO
| Category:
Control Unit
| Size: 3.05 MB
Table of Contents
Deutsch
5
Table of Contents
3
Table of Contents
5
Notes about this Documentation
6
Validity of this Documentation
6
Copyright
6
Symbols
7
Number Notation
9
Font Conventions
9
Table 1: Number Notation
9
Table 2: Font Conventions
9
Technical Condition of Specified Devices
10
Use of the TO-PASS Telecontrol Modules in Compliance with Underlying Provisions
10
Personnel Qualification
10
Subject to Changes
10
Legal Bases
10
Important Notes
10
Disclaimer
11
Firmware Licensing Terms
11
Firmware with Open Source GPL
11
Block Rounding for GPRS Connections
11
Safety Advice (Precautions)
12
Device Description
15
Scope of Delivery
15
Use
15
Table 3: Overview of Functions
16
Figure 1: Front View
17
View
17
Connectors
18
GSM Antenna
18
GPS Antenna
18
Figure 2: GSM Antenna Connection
18
Figure 3: GPS Antenna Connection
18
Operating Voltage
19
Figure 4: Terminal Assignment for Operating Voltage
19
Table 4: Terminal Assignment for Operating Voltage
19
Table 5: WAGO Ground Wire Terminals
20
Telecontrol Module
20
Grounding of the TO-PASS
20
Insulated Assembly
20
Framework Assembly
20
Grounding
20
Shielding
21
General
21
Bus Lines
21
Signal Lines
21
WAGO Shield Connecting System
22
Figure 5: Example of the WAGO Shield Connecting System
22
Digital Inputs
23
Figure 6: Terminal Assignment for Digital Inputs
23
Table 6: Terminal Assignment for Digital Inputs
23
Table 7: Counter Input Pin Assignments
24
Counter Inputs
24
Figure 7: Counter Input Pin Assignments
24
Analog Inputs
25
Figure 8: Terminal Assignment for Analog Inputs
25
Table 8: Terminal Assignment for Analog Inputs
25
Digital Outputs
27
Figure 9: Terminal Assignment for Digital Outputs
27
Table 9: Terminal Assignment for Digital Outputs
27
Serial Interface to PC
28
Figure 10: Serial Interface to the PC and MODBUS Interface
28
Table 10: Serial Interface to the PC
28
Table 11: PC Interface Cable Assignment
28
Table 12: Display Elements
29
Display Elements
29
Figure 11: Display Elements
29
Technical Data
30
Housing
30
Supply
30
GSM Antenna Connection
30
Table 13: Technical Data Housing
30
Table 14: Technical Data Supply
30
Table 15: Technical Data GSM Antenna Connection
30
Table 19: Technical Data Counter Inputs
31
Table 18: Technical Data Digital Inputs
31
Table 17: Technical Data GSM Communication
31
Counter Inputs
31
Table 16: Technical Data GPS Antenna Connection
31
GSM Communication
31
GPS Antenna Connection
31
Digital Inputs
31
Analog Inputs
32
Digital Outputs
32
Data and Event Logger
32
Table 20: Technical Data Analog Inputs
32
Table 21: Technical Data Digital Outputs
32
Table 22: Technical Data Data and Event Logger
32
Approvals
33
Standards and Guidelines
33
Figure 12: Mounting the TO-PASS ® Telecontrol Module to the DIN Rail
34
Mounting
34
Mounting the TO-PASS ® Telecontrol Module to the DIN Rail
34
Removing the TO-PASS ® Telecontrol Module from the DIN Rail
35
Figure 13: Removing the TO-PASS ® Telecontrol Module from the DIN Rail
35
Connect Devices
36
Connecting the Push-Wire Connections to the Conductor
36
Connection Examples
37
Digital Inputs
37
Figure 14: Connection Example for a Switch at DI1 Input
37
Counter Inputs
38
Figure 15: Connecting Example, Switching Contact at Counter Input DI1
38
Figure 16: Connection Example of Transducer with Current Output at Input AI1
39
Analog Inputs
39
Current Measurement
39
Voltage Measurement
40
Figure 17: Connection Example for Voltage Measurement Via U/I Converter at
40
Digital Outputs
41
Figure 18: Example of Connection of Relay at Output DO1
41
Commissioning
42
Installing the Operating Software
42
Starting the TO-PASS ® Telecontrol Module
43
Parameterizing
45
General Settings
45
Figure 19: General Settings
45
Table 23: General Settings
45
Reading Parameters from the Module
47
Figure 20: Configuring the Identity
48
Identity
48
Table 24: Configuring the Identity
49
Addresses
50
Figure 21: Configuring the Addresses
50
Table 25: Configuring the Addresses
51
Configuring Inputs and Outputs
53
Digital Inputs
53
Figure 22: Configuring Digital Inputs 1
53
Figure 23: Configuring Digital Inputs 5
54
Table 26: Configuring of Digital Inputs
54
Multiplex Input
57
Table 27: Configuring Multiplex Operation Settings
58
Figure 24: Configuring Multiplex Operation Settings
58
Multiplex Settings
58
Multiplex Alarm Text
59
Figure 25: Configuring Multiplex Operation Alarm Texts
59
Table 28: Configuring Multiplex Operation Alarm Texts
59
Analog Inputs
60
Figure 26: Configuring the Analog Inputs
60
Table 29: Configuring the Analog Inputs
60
Digital Outputs
62
Figure 27: Configuring the Digital Outputs
62
Table 30: Configuring the Digital Outputs
62
Limit Messages for Analog Inputs
63
Limit Messages for Counter Inputs
63
Alarm Messages for Digital Inputs
63
Configuring Error Detectors
63
Acknowledgement
65
Figure 28: : Configuring the Acknowledgment Response
65
Table 31: Configuring the Acknowledgement Response
65
Transmission Repeat Times
66
Figure 29: Configuring the Transmission Repeat Times
66
Table 32: Configuring the Transmission Repeat Times
67
Time Adjustment
69
Figure 30: Setting the Time Adjustment
69
Table 33: Setting the Time Adjustment
69
Table 34: Configuring the Data Logger
70
Data Logger
70
Figure 31: Configuring the Data Logger
70
GPS Settings
71
Figure 32: Configuring the GPS Settings
71
Table 35: Configuring the GPS Settings
72
Writing Parameters to the Module
73
Operation
74
Remote Query of Process Values
74
Remote Polling Via SMS
75
Table 36: SMS Format
75
Table 37: Items Added to SMS for Counter Inputs
76
Table 38: Counter Status
76
Operating Program
77
Remote Polling Using the TO-PASS
77
Inputs/Outputs
78
Figure 33: Visualization of the Process Values
78
Gps
79
Figure 34: GPS Process Values
79
Table 39: GPS Process Values
79
Counters
80
Figure 35: Counter Process Values
80
Telecontrol
81
Telecontrol Via SMS
82
Setting or Resetting a Digital Output
82
Table 40: Example of Parameters for Set DO
82
Changing the Counter Value or Status
83
Table 41: Control Commands for Counters
83
Telecontrol with the TO-PASS
84
Operator Program
84
Inputs/Outputs
85
Figure 36: Visualization of the Process Values
85
Counters
86
Figure 37: Counter Process Values
86
Acknowledging Error Messages
87
Switching to Standby
88
Displaying the Data Logger (DSP)
89
Table 42: Navigation DSP
89
Displaying the Event Logger (ESP)
91
Diagnostics
92
Test Inputs and Outputs
92
Figure 38: Test Inputs and Outputs
92
Testing the Counter Inputs
93
Figure 39: Testing Counters
93
Testing the Connection
94
Figure 40: Testing the Connection
94
Testing the Modem
95
Figure 41: Testing the Modem
95
English
96
List of Figures
96
List of Tables
97
Advertisement
Advertisement
Related Products
WAGO 761-316
WAGO 761-216
WAGO 761-113
WAGO 761-214
WAGO WAGO-TO-PASS 761
WAGO 761-111
WAGO 761-112
WAGO 761-217
WAGO 761-110
WAGO 761-210
WAGO Categories
I/O Systems
Control Unit
Power Supply
Switch
Controller
More WAGO Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL