Table of Contents
Table of Contents
3
Introduction
6
About this Guide
6
About the 2GIG Go!Control System
6
Important Information
6
Installing the System in Residential Settings
6
Installing the System in Commercial Settings
7
System Features
7
Optional Accessories
8
System Configuration
9
Control Panel Features
10
External Features
10
Internal Features
11
Installation Outline
12
Wireless Installation Tips
13
Sensors and Accessories
14
Wireless System Sensors
14
System Accessories
14
Installation
15
Control Panel Mounting Plate
15
Wireless Sensors
16
Hardwired Loops
16
Wiring
16
Remote Alarm Sounder
16
LTE (Cellular) Radio Module
17
Control Panel Wiring Diagram
18
Control Panel Wiring
19
Terminal Block Wiring Diagram
19
Backup Battery Connection and Power Supply Wiring
19
Wire Size and Length
19
Control Panel and Power Supply Mounting
20
Commercial Installations
21
NFPA Standard 72
22
Main Display Screens
23
Home Screen
23
Security Screen
23
Arming Screen
23
Menu Screen
23
System Status Screen
24
Toolbox and Installer Toolbox
25
Toolbox Screens
25
Accessing the Toolbox
25
Installer Toolbox Screens
25
Accessing the Installer Toolbox
25
Accessing the System Configuration for System and Sensor Programming
25
System Configuration Screens
26
System Status Icons
27
AC Power On/Off
27
Sounder Disabled
27
Low Backup Battery
27
Test Mode
27
Touch Screen Keypad Traffic
27
Cell Radio
27
Interior Sensor Open
27
Programming Navigation
28
Questions Without Sub-Options
28
Questions with Sub-Options
28
Questions with Data Entry
28
Additional Buttons
29
Programming Outline
30
ANSI/SIA CP-01 Compliance
30
Programming Question Table
31
Zone Numbering
34
Sensor Types (Zones)
35
Sensor Type (Zone)
36
Description
37
Voice Descriptors
37
Installer Programming
40
Account Registration
40
Wireless (RF) Sensor Programming
40
Q1: RF Sensor Programming Outline
41
Summary of RF Sensor # Screen
41
RF Sensor Programming Questions
41
Wired Sensor Programming
43
Summary of Wired Sensor # Screen
44
Wired Sensor Programming Questions
44
Wireless (RF) Key Fob Programming
46
Key Fob Programming Outline
47
Q3: RF Key Fob Programming Outline
47
Summary of RF Key Fob # Screen
47
RF Key Fob Programming Questions
47
Wireless (RF) Keypad Programming
48
RF Keypad Programming Outline
49
Q4: RF Key Pad Programming Outline
49
Summary of RF Keypad Screen
49
RF Keypad Programming Questions
49
Control Panel Programming
51
Programming Questions
51
Q1: RF Sensor Programming
51
Q2: Wired Sensor Programming
51
Q3: RF Key Fob Programming
51
Q4: RF Keypad Programming
51
Q5: Exit Delay, in Seconds (45-120)
51
Q6: Entry Delay 1, in Seconds (30-240)
51
Q7: Entry Delay 2, in Seconds (30-240)
51
Q13: 2-Way Voice (0-2)
51
Q16: Police Emergency Key (0-2)
52
Q17: Fire Emergency Key (0-1)
52
Q18: Emergency Key (0-1)
52
Q19: Quick Arming (0-1)
52
Q20: Swinger Shutdown Count (1-6)
52
Q21: Siren Supervision Time (0-3)
52
Q22: CS Lack of Usage Notification Time (0-255)
52
Q23: Radio Modem Network Failure Time (0-255)
52
Q24: Radio Modem Network Failure Causes Trouble (0-1)
52
Q25: Radio Modem Network Failure Reports (0-1)
53
Q26: Auto Stay (0-1)
53
Q27: Exit Delay Restart (0-1)
53
Q28: Quick Exit (0-1)
53
Q29: Periodic Test, in Days (0-255)
53
Q31: Cancel Time, in Minutes (5-255)
53
Q32: Cancel Display (0-1)
53
Q33: Cross Sensor 47-48 (0-1)
53
Q34: Cross Sensor Timeout, in Seconds (10-120)
53
Q38: Time to Detect AC Loss, in Minutes (0-30)
54
Q35: Abort Window Dialer Delay (0-2)
54
Q36: Burglary Bell Cutoff (0 to 4)
54
Q37: Fire Bell Cutoff (0-4)
54
Q39: Random AC Loss Report Time (0-1)
54
Q43: Installer Code (4 Digits)
54
Q44: Lock Installer Programming (0-2)
54
Q45: Lock Default Programming (0-2)
55
Q46: Trouble Doesn't Sound at Night (0-1)
55
Q47: Trouble Resound after Hold off (0-7)
55
Q49: Programming Mode Entry Reports to CS (0-1)
55
Q50: Trouble Reports to CS (0-1)
55
Q51: Manual Bypass Reports to CS (0-1)
55
Q52: AC Loss Reports to CS (0-1)
55
Q53: System Low Battery Reports to CS (0-1)
56
Q54: RF Low Battery Reports to CS (0-1)
56
Q55: Opening Reports to CS (0-1)
56
Q56: Closing Reports to CS (0-1)
56
Q57: Alarm Restore Reports to CS (0-1)
56
Q58: Trouble Restore Reports to CS (0-1)
56
Q59: Bypass Restore Reports to CS (0-1)
56
Q60: AC Restore Reports to CS (0-1)
56
Q61: System Low Battery Restore Reports to CS (0-1)
56
Q62: RF Low Battery Restore Reports to CS (0-1)
56
Q64: Smart Test Reports
57
Q65: RF Jam Causes Trouble (0-1)
57
Q66: Daylight Saving (0-1)
57
Q67: Daylight Saving Start Month (01-12)
57
Q68: Daylight Saving Start Monday (1-7)
57
Q69: Daylight Saving End Month (01-12)
57
Q70: Daylight Saving End Sunday (1-7)
57
Q71: System Tamper Causes Trouble (0- 1)
57
Q72: Quick Bypass (0-1)
57
Q73: Disarming Keyfob after Alarm (Alert) (0-1)
57
Q75: Auto Unbypass for Manual Bypass (0-1)
58
Q76: Force Bypass Reports (0-1)
58
Q77: Event Log (0-3)
58
Q79: Z-Wave Feature (0-3)
58
Q80: Z-Wave Switches Feature (0 to 1)
58
Q81: Z-Wave Thermostats Feature (0 to 1)
58
Q82: Z-Wave Door Locks Feature (0-1)
58
Q83: Select Temperature Display Units (0-1)
58
Q84: Services Require Master Code (0 to 1)
58
Q85: Master User Access to Z-Wave Toolbox (0-1)
59
Q86: Disable Siren after Two-Way Audio (0-1)
59
Q87: Keyfob/Remote Arming Mode on System Not Ready (0-2)
59
Q89: Allow Backlight Always on (Demo Mode) (0-1)
59
Q90: Energy Feature (0 to 1)
59
Q91: Radio Modem Supplier
59
Q92: Select Network Device (0 to 1)
59
Q93: Enter Broadband Network Failure Time (1-255)
60
Q94: Select Broadband Network Failure Causes Trouble (0 to 1)
60
Q95: Select Broadband Network Failure Reports (0 to 1)
60
Q96: Select Send Report 3 Times on Panel Tamper (0 to 1)
60
Q97: Select Sound on Normal Closing Acknowledgment (0 to 1)
60
Final Installation Setup
61
Exiting Programming (System Configuration)
61
Access the Installer Toolbox
63
Disable/Enable Sounder
63
Disable the Sounder
63
Enable the Sounder
63
Sensor Type (Zone) Report Test
63
Walk Test
63
Radio Status Test
64
Cell Phone Test
64
Restore Default System Configuration
65
Soft Reset
65
Hard Reset
65
Regulatory Information
66
Wireless Product Notice
66
FCC Notice
66
Industry Canada Notices
66
Commercial Regulatory Listings
67
Limited Warranty
68
Advertisement
Nortek Security & Control 2GIG e Series Quick Start Manual (2 pages)
AUDIO DETECTOR
Brand:
Nortek Security & Control
| Category:
Security Sensors
| Size: 0.44 MB
Advertisement
Related Products
Nortek Security & Control 2GIG GC2
Nortek Security & Control 2GIG GC2e
Nortek Security & Control 2GIG Z-Wave Plus
Nortek Security & Control GC2e
Nortek Security & Control Categories
Gate Opener
Keypad
Security Sensors
Security System
Remote Control
More Nortek Security & Control Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL