Sign In
Upload
Manuals
Brands
Mindray Manuals
Measuring Instruments
BC-2800
Mindray BC-2800 Hematology Analyzer Manuals
Manuals and User Guides for Mindray BC-2800 Hematology Analyzer. We have
3
Mindray BC-2800 Hematology Analyzer manuals available for free PDF download: Operator's Manual, Service Manual, Operation Manual
Mindray BC-2800 Operator's Manual (286 pages)
Auto Hematology Analyzer
Brand:
Mindray
| Category:
Measuring Instruments
| Size: 2.74 MB
Table of Contents
Table of Contents
7
1 Using this Manual
13
Introduction
13
Who Should Read this Manual
14
How to Find Information
15
Conventions Used in this Manual
16
Special Terms Used in this Manual
17
Symbols
18
2 Understanding Your Analyzer
25
Introduction
25
Intended Use
26
User Interface
27
Lcd
30
Input Devices
30
Recorder
32
Keyboard Interface
32
Serial Ports
32
Parallel Port
32
Power Supply for the Floppy Disk Drive
32
Power Indicator
32
Optional Devices
32
Instrument Software
33
Main Screen
33
Screen Saver
34
System Menu
35
Reagents, Controls and Calibrator
37
Diluent
37
Lyse
37
Rinse
38
E-Z Cleanser
38
Probe Cleanser
38
Controls and Calibrator
38
3 Understanding the System Principles
39
Introduction
39
Aspiration
40
Dilution
41
WBC/HGB Measurement
42
Volumetric Metering
42
Measurement Principles
43
Derivation of WBC-Related Parameters
44
Hgb
45
RBC/PLT Measurement
46
Volumetric Metering
46
Measurement Principles
47
Derivation of RBC-Related Parameters
47
Derivation of PLT-Related Parameters
49
Wash
50
4 Installing Your Analyzer
51
Introduction
51
Installation Requirements
52
Space Requirements
52
Power Requirements
52
General Environment
53
Unpacking
54
Unpacking and Inspecting the Analyzer
54
How to Move the Analyzer
54
Installation Procedure
55
Connecting Regents
55
Installing Recorder Paper
59
Connecting the Keyboard
60
Connecting the Printer (Optional)
60
Connecting the Bar-Code Scanner (Optional)
60
Starting the Analyzer
61
5 Customizing the Analyzer Software
63
Introduction
63
Password
64
Entering the Administrator Password
64
Resuming the Common User Password
65
Editing Settings
66
Reagent
67
Printing and Communication Settings
68
Date and Time
73
Gain
75
Count
78
Reference Range
82
Auto Maintain
85
Other Settings
87
6 Operating Your Analyzer
93
Introduction
93
Initial Checks
94
Power-On
95
Daily Quality Control
96
Selecting Analysis Mode
97
Sample Collection and Handling
98
Whole Blood Samples
98
Prediluted Samples
99
Running Whole Blood Samples
101
Entering Sample Information
101
Running the Samples
107
Special Functions
108
Running Prediluted Samples
111
Entering Sample Information
111
Running the Samples
116
Special Functions
117
Shutdown
120
7 Reviewing Sample Results
123
Introduction
123
Browsing All Sample Results
124
Browsing in the Histogram Mode
124
Browsing in the "Table" Mode
129
Searching for Interested Sample Results
139
Starting a Search
139
Reviewing Search Result in the "Table" Mode
141
Reviewing Search Result in the "Histogram" Mode
151
8 Using the QC Programs
157
Introduction
157
QC with Controls
158
QC Editing
158
Running the Controls
162
Reviewing QC Results
166
X-B Analysis
171
QC Editing
171
Running X-B Analysis
174
Reviewing X-B Results
174
9 Using the Calibration Programs
177
Introduction
177
When to Calibrate
178
How to Calibrate
179
Preparing Your Analyzer
179
Calibration Using Calibrator Program
180
Fresh Blood Calibration
186
Manual Calibration Program
193
10 Maintaining Your Analyzer
197
Introduction
197
General Guidelines
198
Using the "Maintenance" Program
199
Diluent Prime
200
Rinse Prime
201
Lyse Prime
202
Zap Aperture
203
Flush Aperture
204
Probe Cleanser Cleaning
205
E-Z Cleanser Cleaning
207
Lyse Test
209
Clean Bath
211
Drain Bath
212
Drain Tubing
214
Clean Probe Wipe
215
Prepare to Ship
217
Using the "Status" Program
219
Using the "Self-Test" Program
220
Testing the Fluidic System
221
Testing Motors and Recorder/Printer
221
Testing Valves
222
Testing A/D Interrupt
223
Log
224
Viewing System Configuration
226
Printing Management
227
Calibrating Sample Probe Position
228
Replacing the Probe Wipe
232
Replacing the Filter of the Vacuum Chamber
233
Maintaining Recorder
235
11 Troubleshooting Your Analyzer
237
Introduction
237
Errors Without Available Error Messages
238
Errors Indicated by Error Messages
239
12 Appendices
249
A Index
249
B Specifications
253
Advertisement
Mindray BC-2800 Service Manual (109 pages)
Auto Hematology Analyzer
Brand:
Mindray
| Category:
Measuring Instruments
| Size: 2.68 MB
Table of Contents
Table of Contents
7
Basic Functions of the CPU Board
9
Chapter1 Hardware
9
General
9
Schematic
9
Power Distribution of the CPU Board
11
Power Supply
11
Arrangement of the CPU Clock
12
Rtc
12
CPU and Peripheral Devices
13
Wdt
13
Dom
14
Flash
14
Sdram
14
Analog Inputs and Outputs
16
Signals of Blood Cell Counts
16
Signals of LCD Contrast
16
Signals of System Monitoring
16
Digital Inputs and Outputs
17
Gpios
17
Parallel Port and PS/2 Port
17
Serial Port
17
Basic Blocks
19
Basic Functions
19
Driving Board
19
Power Block
19
Control/Drive Circuit of Sample Probe Mechanism
20
Control/Drive Circuit of the Elevator Motor
20
Motor Control Block
20
Serial Communication Circuit
20
Testable Signals
21
Connection Schematic
22
Display Unit
22
Function of the Adapter
22
Introduction of the Adapter
22
Schematic of the Adapter
23
Architecture of the Adapter
24
Detailed Description
24
Functions of the Keypad Adapter
24
Buzzer Control
25
Control of LCD Brightness
25
Chapter2 Fluidic System
27
Fluidic System
27
Construction of Fluidic System
28
Sample Probe Assembly
28
Composition of Fluidic System
29
Aspiration/Dispensing Module
30
Functional Modules
30
Interaction of the Functional Modules
30
Counting Module
31
Washing Exterior and Interior of Sample Probe
33
Washing Module
33
Washing of the Front and Back Baths
34
Hydraulic Module
35
Mixing Module
36
Pressure/Vacuum Module
36
Waste Discharging Module
37
Counting Procedure
38
Dilution
38
Prediluted Mode
38
Whole Blood Mode
38
Diluting Procedure of Prediluted Mode
39
Volume Range of Blood Cells
39
Chapter3 Disassembling The Analyzer
41
Main Unit Structure
41
Main User Interfaces
41
Left View
42
Disassembling the Main Unit
43
Removing the Left, Right and Top Covers
43
Removing the Front Cover
44
Removing the Keypad
45
Removing the LCD and Adaptor
45
Removing the LCD Assembly
45
Removing the Power Shielding Box
46
Removing the Transformer
47
Removing Valves
47
Removing the Sample Probe Assembly
48
Removing the Syringe Assembly
49
Removing the Vacuum Chamber and Volumetric Metering Tube Assembly
49
Removing the Pump Assembly
50
Adjusting Sample Probe and Replacing Wipe Block
51
Adjusting Sample Probe Position
51
Localizer
51
Accessing Elevator Motor
52
Elevator Motor Screen
52
Removing Screws
53
Sample Probe on the Top of the Bath
53
Inserting Sample Probe into Wipe Block
54
Replacing Wipe Block
54
Installing Probe Wipe
55
A Normal Histogram
57
Chapter4 Histograms And Pulse Graphs
57
Increased Granulocytes
58
Increased Lymphocytes
58
No Lyse Reagent or Poor Hemolysis
58
Tumor Patient
58
Common Pulse Graphs
59
Normal Pulse Graphs
59
Pulse Graphs
59
WBC Pulses
59
Pulse of Normal PLT Background Check
60
Pulse of Normal RBC Background Check
60
Chapter5 Adjustment
65
Gain Adjustment
65
Chapter 6 Maintenance
67
Regular Maintenance
68
Recommended Regular Maintenance
69
Entering Maintenance Screen
70
Maintenance Screen
70
System Maintenance
70
Diluent Prime
71
Diluent Priming Screen
71
Rinse Prime
72
Rinse Priming Screen
72
Lyse Prime
73
Lyse Priming Screen
73
Zap Aperture
73
Flush Aperture
74
Zapping Aperture
74
Probe Cleanser Cleaning
75
E-Z Cleanser Cleaning
76
Recommending Probe Cleanser Cleaning
76
Lyse Test
77
Removing the Two Screws
77
Removing Right Plate
78
Shielding Box
78
Bath
79
Clean Bath
79
Drain Bath
79
Draining Tubing
80
Cleaning Probe Wipe Block
81
A Dialog Box of Prepare to Ship
82
Preparing to Ship
82
Entering Status Screen
83
System Status
83
Entering Self-Test Screen
84
System Self-Test
84
Count Time
85
Pressure
85
Testing Tubing
85
Vacuum
85
Elevator Motor
86
Rotation Motor
86
Syringe Motor
86
Testing Motors and Recorder/Printer
86
Testing Circuits
87
Testing Valves
87
Testing A/D Converter
88
Entering Log
89
Log
89
Log Screen
89
System Configuration
91
Entering Print Screen
92
Printing Management
92
Adjusting Sample Probe and Replacing Probe Wipe
94
Chapter7 Troubleshooting
95
Error Codes
96
Background Abnormal
97
Environmental Temperature Abnormal
97
HGB Error
97
Solutions
97
RBC Clog
98
WBC Bubbles
98
RBC Bubbles
99
Communication Error
100
Printer out of Paper
100
Scanner Communication Error
100
Scanner Error
100
Diluent Expired
101
Lyse out
101
Press Bar up
101
Rinse Expired
101
A/D Error
102
Elevator Motor Error
102
Rotation Motor Error
102
Syringe Motor Error
102
Diluent out
103
File Error
103
Rinse out
103
Waste Full
103
Chapter8 List Of Spare Part
105
Appendix Bc-2800 Error Message
107
Mindray BC-2800 Operation Manual (92 pages)
Auto Hematology Analyzer
Brand:
Mindray
| Category:
Measuring Instruments
| Size: 3.43 MB
Table of Contents
Warranty
4
Safety Symbols
7
Supplementary Data
9
Service Assistance
9
Transportation and Storage Environment
17
Display a Reas
21
Input Devices
22
Screen Saver
23
System Menu
24
Operation Summary
25
Installation
26
Space Requi Rement
27
Power Requirements
27
Tubin G Connection
28
Waste Disposal
30
Loading Recordi Ng Paper
31
Entering Sample Information
33
Preparing Sampl es
41
Reference Range
46
Chapter 8 Maintenance
55
Regular Maintenance
55
Special Notes
55
Recommended Regular Maintenance
56
System Status
57
System Self-Test
59
Testing Motors and Recor Der/Prin Ter
60
Testing Valves
61
System Configuration
65
Printing Management
66
Troubleshooting
73
Error Codes
74
Printer out O F Paper
79
Advertisement
Advertisement
Related Products
Mindray BC-20s
Mindray BC-3000 Plus
Mindray BC-5380
Mindray BC-1800
Mindray BC-30s
Mindray BA-88A
Mindray BS-130
Mindray BS-190
Mindray BS-180
Mindray BS-200
Mindray Categories
Medical Equipment
Measuring Instruments
Monitor
Diagnostic Equipment
Water Pump
More Mindray Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL