Manuals and User Guides for Covidien Nellcor PM10N. We have
3
Covidien Nellcor PM10N manuals available for free PDF download: Operator's Manual, Service Manual, Home Use Manual
Covidien Nellcor PM10N Operator's Manual (112 pages)
Portable SpO2 Patient Monitoring System
Brand:
Covidien
| Category:
Medical Equipment
| Size: 7.38 MB
Table of Contents
Table of Contents
3
1 Introduction
11
Overview
11
Safety Information
11
Safety Symbols
11
Table 1-1. Safety Symbol Definitions
11
Explosion, Shock, and Toxicity Hazards
12
Patient Monitoring and Safety
12
Monitoring System Operation and Service
13
Monitoring System Readings
14
Sensors, Cables, and Other Accessories
14
Electromagnetic Interference
15
Connections with Other Equipment
15
Monitoring System Storage, Transport, and Disposal
16
Obtaining Technical Assistance
16
Technical Services
16
Related Documents
17
Warranty Information
17
2 Product Overview
19
Overview
19
Product Description
19
Intended Use
20
Product Views
21
Front Panel and Display Components
21
Figure 2-1. Front Panel Components
21
Figure 2-2. Display Components
22
Table 2-1. Display Colors
24
Rear Panel
25
Product and Carton Label Symbols
25
Table 2-2. Symbol Descriptors
25
Figure 2-3. Rear Panel Components
25
3 Installation
27
Overview
27
Unpacking and Inspection
27
Table 3-1. Standard Items
27
Setup
28
Using the Batteries
28
Connecting a Nellcor™ Pulse Oximetry Sensor
29
Figure 3-1. Sensor Port Cover
29
Figure 3-2. Interface Cable (DEC-4) or Sensor Cable Connection
29
Figure 3-3. Interface Cable (Optional) Connection to Sensor
30
4 Operation
31
Overview
31
Operation Basics
31
Power on the Monitoring System
31
Figure 4-1. Example Initial Screen
32
Figure 4-2. Main Monitoring Screen
32
Power off the Monitoring System
33
Navigate the Menus
33
Menu Structure and Factory Defaults
34
Table 4-1. Menu Structure and Available Options
34
Patient Monitoring
35
Set Patient Mode
35
Figure 4-3. Patient Mode Menu
36
Save a Spot Reading
37
Alarms and Alarm Limits Management
37
Alarm Indicators
37
Figure 4-4. Save Spot Reading
37
Table 4-2. Alarm Conditions
38
Silencing an Audible Alarm
39
Adjusting Alarm Limits
40
Figure 4-5. Main Monitoring Screen
40
Figure 4-6. Alarm Limits Menu
41
Using the Satseconds™ Alarm Management System
42
Figure 4-7. High Spo2 Setting
42
Additional Patient Modes
43
Set Response Mode
43
Figure 4-8. Satseconds™ Setting
43
Set Homecare Mode
44
Figure 4-9. Response Mode Menu
44
Figure 4-10. Patient Mode Menu Item
45
Figure 4-11. Homecare Mode Menu Item
45
Figure 4-12. Pass Code Entry for Homecare Mode
46
Figure 4-13. Prompt to Delete or Keep Monitoring History
46
Set Sleep Study Mode
47
Figure 4-14. Homecare Mode Monitoring Screen
47
Figure 4-15. Patient Mode Menu Item
47
Figure 4-16. Sleep Study Mode Menu Item
48
Figure 4-17. Pass Code Entry for Sleep Mode
48
Adjust Brightness and Volume
49
Figure 4-18. Sleep Study Mode
49
Adjust Brightness
50
Figure 4-19. Device Settings Menu
50
Figure 4-20. Brightness Setting Menu
50
Adjust Volume
51
Figure 4-21. Sound Settings Menu
51
Screen Saver
52
Service Menu
52
Maintenance Reminder
52
Figure 4-22. Example Volume Setting
52
Data Management
53
Monitoring History
53
Overview
53
Figure 5-1. Monitoring History Menu
54
Figure 5-2. Monitoring History Screen
54
Figure 5-3. Continuous Data Screen (Interval 100) and Scroll Bar
55
Table 5-1. Monitoring Status Codes
55
External Data Communication
56
Monitoring History (Trend Data) Download
56
Figure 5-4. Transfer Data Type
58
Figure 5-5. Transfer Data by USB
58
Figure 5-6. Sample Trend Data Printout
59
Figure 5-7. Bridge Driver Installer Window
60
Figure 5-8. New Hardware Wizard Screen
61
Figure 5-10. Hardware List in Device Manager Window
62
Figure 5-9. Device Manager Button under Hardware Tab
62
Figure 5-11. Sample Initial USB to UART Bridge Properties Window
63
Firmware Upgrades
64
Figure 5-12. Baud Rate List under Port Settings Tab
64
Performance Considerations
65
Overview
65
Oximetry Considerations
65
Pulse Rates
65
Saturation
65
Patient Conditions
66
Sensor Performance Considerations
66
Reducing EMI (Electromagnetic Interference)
68
Preventive Maintenance
69
Cleaning
69
Overview
69
Battery Maintenance
70
Figure 7-1. Monitoring System Cleaning
70
Recycling and Disposal
70
Periodic Safety Checks
71
Service
71
8 Troubleshooting
73
Overview
73
General
73
Error Conditions
74
Table 8-1. Common Problems and Resolutions
74
Return
76
9 Accessories
77
Overview
77
Nellcor™ Pulse Oximetry Sensors
77
Table 9-1. Nellcor™ Sensor Models and Patient Sizes
77
Biocompatibility Testing
78
Nellcor™ Sensor Features
78
Optional Equipment
79
Figure 9-1. Standard Protective Covers
79
10 Theory of Operations
81
Overview
81
Theoretical Principles
81
Automatic Calibration
82
Functional Testers and Patient Simulators
82
Unique Technologies
83
Functional Versus Fractional Saturation
83
Measured Versus Calculated Saturation
84
Data Update Period, Data Averaging, and Signal Processing
84
System Features
85
Nellcor™ Sensor Technology
85
Satseconds™ Alarm Management Parameter
86
11 Product Specifications
91
Overview
91
Physical Characteristics
91
Electrical
92
Environmental Conditions
92
Table 11-1. Transport, Storage, and Operating Condition Ranges
92
Tone Definition
93
Table 11-2. Tone Definitions
93
Sensor Accuracy and Ranges
94
Table 11-3. Trends
94
Table 11-4. Pulse Oximetry Sensor Accuracy and Ranges
94
Sound Pressure
95
Table 11-5. Sound Pressure in Decibels
95
Product Compliance
96
Manufacturer's Declaration
96
Electromagnetic Compatibility (EMC)
97
Table 11-6. Electromagnetic Emissions Guidelines and Compliance
97
Table 11-7. Electromagnetic Immunity Guidelines and Compliance
98
Table 11-8. Recommended Separation Distance Calculations
99
Table 11-9
100
Sensor and Cable Compliance
101
Table 11-10. Recommended Separation Distances
101
Table 11-11. Sensor and Cable Length
101
Safety Tests
102
Table 11-12. Touch Current Specification
102
Essential Performance
103
Table 11-13. Patient Leakage Current Specification
103
A Clinical Studies
105
Overview
105
Methods
105
Study Population
106
Study Results
106
Adverse Events or Deviations
107
Conclusion
107
Advertisement
Covidien Nellcor PM10N Service Manual (112 pages)
Portable SpO2 Patient Monitoring System
Brand:
Covidien
| Category:
Medical Equipment
| Size: 5.98 MB
Table of Contents
Table of Contents
3
Overview
9
Explosion, Shock, and Toxicity Hazards
10
Safety Information
10
Safety Symbols
10
Table 1-1. Safety Symbol Definitions
10
Service Procedures
11
Monitoring System Operation and Service
12
Monitoring System Readings
13
Patient Monitoring and Safety
13
Electromagnetic Interference
14
Sensors, Cables, and Other Accessories
14
Connections with Other Equipment
15
Monitoring System Storage, Transport, and Disposal
15
Obtaining Technical Assistance
16
Related Documents
16
Warranty Information
17
Technical Services
16
Service Menu Options
19
Overview
19
Safety Reminders
19
Service Menu Overview
19
Table 2-1. Service Menu Settings
20
Figure 2-1. Service Menu
21
Permission to Mute Alarm
21
Power on Settings
21
Alarm Silence Duration
22
Battery Type
22
Communication Settings
22
Date/Time Settings
22
Power Saving Settings
22
About Monitor
23
Alarm Priority Settings
23
Dynamic Password
23
Enable Pcsync Mode
23
Languages
23
Covidien Service
24
Data Management
25
External Data Communication
25
Overview
25
Monitoring History Download
26
Figure 3-1. Mini-USB Port
27
Figure 3-2. Transfer Data Type
28
Figure 3-3. Transfer Data by USB
28
Figure 3-4. Sample Monitoring History Printout
29
Table 3-1. Monitoring Status Codes
30
Figure 3-5. Sample Bridge Driver Installer Window
31
Figure 3-6. Sample New Hardware Wizard Screen
31
Figure 3-7. Device Manager Button, Hardware Tab
32
Figure 3-8. Sample Hardware List in Device Manager Window
33
Figure 3-9. Sample Initial USB to UART Bridge Properties Window
34
Figure 3-10. Baud Rate List, Port Settings Tab
35
Firmware Upgrade
35
Figure 3-11. Firmware Upgrade Mode
36
Figure 3-12. Firmware Upgrade, Pcsync™* Utility
36
Figure 3-13. Firmware Upgrade Process
37
Figure 3-14. POST Screen and Firmware Version
38
Modification and Testing
39
Overview
39
Required Equipment
40
System Performance Tests
40
Power-On Self-Test (POST)
40
Table 4-1. Required Test Equipment
40
Battery Status
41
Figure 4-1. Power-On Self-Test Sequence
41
Patient Modes
42
Figure 4-2. Change Patient Mode Menu
42
Homecare Mode
43
Table 4-2. Patient Modes
43
Figure 4-3. Homecare Mode Menu Item
43
Sleep Study Mode
44
Figure 4-4. Homecare Mode Monitoring Screen
44
Dynamic Passwords
45
Figure 4-5. Sleep Study Mode Menu Item
45
Figure 4-6. Service Menu
46
Figure 4-7. Dynamic Password Menu (Homecare to Standard Example)
46
Date and Time
47
Figure 4-8. Password Set or Reset (Homecare to Standard Example)
47
Figure 4-9. Date/Time Settings
47
Operational and Functional Tests
48
General Operation Tests
48
Figure 4-10. Sensor Port
48
Figure 4-11. Sensor Port
49
Figure 4-13. Low Pulse Alarm Limit of 160BPM
51
Figure 4-14. Alarm Silence Duration Setting of 30 Seconds
52
Figure 4-15. Permission to Mute Alarm
53
Figure 4-16. Confirmation for Muted Alarm
53
Figure 4-20. Brightness Setting
58
Figure 4-21. "Spot Reading Saved" Message
59
Figure 4-22. Monitoring History Spot Data
59
Figure 4-23. Sensor Disconnect Alarm Priority Setting
60
Figure 4-24. Sensor off Alarm
61
Figure 4-25. Screen Saver Time Setting
62
Functional Tests
64
Figure 4-26. Auto Power off Time Setting
64
Table 4-3. Functional Tests with SRC-MAX
65
Figure 4-27. SRC-MAX Oximetry Tester
66
Figure 4-28. SRC-MAX Tester-Generated Waveform
67
Figure 4-29. SRC-MAX Increase to 200 BPM
68
Figure 4-30. SRC-MAX Decrease to 60 BPM
68
Figure 4-33. SRC-MAX High Modulation
71
Figure 4-34. BPM of 200 with High Modulation
72
Figure 4-35. BPM of 60 with High Modulation
73
Figure 4-37. %Spo2 of 75 with High Modulation
75
Figure 4-39. High Light Condition
77
Figure 4-40. BPM of 200 with High Light Condition
78
Figure 4-41. BPM of 60 with High Light Condition
79
Figure 4-43. %Spo2 of 75 with High Light Condition
81
Figure 4-44. High Modulation and High Light Condition
82
Verification Check Sheets
83
Troubleshooting
85
Overview
85
Troubleshooting Guide
85
Error Conditions by Category
86
Table 5-1. Error Conditions and Resolutions
86
System Error Codes
90
Table 5-2. System Error Codes
90
Return
92
Figure 5-1. Return Packaging
93
Repair
95
Figure 6-1. Exploded View
96
Overview
95
Spare Parts and Accessories
96
Table 6-1. Spare Parts List by Callout Number
96
Required Tools
98
Table 6-2. Monitoring System Accessories
98
Figure 6-2. Standard Cover (3 Shown) and Ambulatory Cover
98
Remove the Batteries
99
Replace the Batteries
99
Battery Replacement
98
Disassembly and Reassembly
100
Front and Rear Assembly Replacement
100
Figure 6-4. Front and Rear Assembly Replacement
101
NELL1SR Board Replacement
102
Main Board Replacement
103
Figure 6-5. NELL1SR Board Replacement
103
Figure 6-6. Main Board Replacement
104
Coin Cell Battery Replacement
105
Figure 6-7. Coin Cell Battery Replacement
105
LCD Replacement
106
Figure 6-8. LCD Replacement
106
PI Cable and Cable Housing Replacement
107
Figure 6-9. PI Cable and Cable Housing Replacement
107
Covidien Nellcor PM10N Home Use Manual (50 pages)
Portable SpO2 Patient Monitoring System
Brand:
Covidien
| Category:
Medical Equipment
| Size: 2.6 MB
Table of Contents
Table of Contents
3
Welcome
5
Safety Information
7
Set up the Monitoring System
11
Monitor the Patient
17
Change the Sensor
35
Clean the Monitoring System and Sensor
37
Accessories
41
Symbols
43
Glossary
45
Index
48
Advertisement
Advertisement
Related Products
Covidien Nellcor PM100N
Covidien Nellcor PM1000N-RR
Covidien Nellcor PM1000N
Covidien Nellcor OxiMax N-600x
Covidien Nellcor Series
Covidien Nellcor GR101704-RR
Covidien Nellcor GR101704
Covidien Nellcor FLEXMAX
Covidien Nellcor FLEXMAX-P
Covidien Nellcor
Covidien Categories
Medical Equipment
Accessories
Thermometer
Measuring Instruments
Water Pump
More Covidien Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL