Sign In
Upload
Manuals
Brands
Anritsu Manuals
Measuring Instruments
Spectrum Master MS2711E
Anritsu Spectrum Master MS2711E Analyzer Manuals
Manuals and User Guides for Anritsu Spectrum Master MS2711E Analyzer. We have
2
Anritsu Spectrum Master MS2711E Analyzer manuals available for free PDF download: Maintenance Manual, User Manual
Anritsu Spectrum Master MS2711E Maintenance Manual (216 pages)
Handheld Spectrum Analyzer
Brand:
Anritsu
| Category:
Measuring Instruments
| Size: 15 MB
Table of Contents
Table of Contents
5
Chapter 1-General Information
9
Introduction
9
Anritsu Customer Service Centers
9
Recommended Test Equipment
10
Replaceable Parts
14
Chapter 2 - Spectrum Analyzer Verification
19
Introduction
19
Frequency Accuracy Verification and Adjustment
20
Single Side Band (SSB) Phase Noise Verification
22
Ms271Xe MM PN: 10580-00254 Rev. N
23
Spurious Response (Second Harmonic Distortion) Verification
24
Resolution Bandwidth Accuracy Verification
26
RBW Test
26
Spectrum Analyzer Absolute Amplitude Accuracy Verification
27
50 Mhz Amplitude Accuracy Verification
27
Amplitude Accuracy Across Frequency Verification
31
Residual Spurious Response Verification
35
Residual Spurious Response Test with Pre Amp off
35
Residual Spurious Response Test with Pre Amp on
36
Displayed Average Noise Level (DANL)
38
Third Order Intercept (TOI) Verification
40
Chapter 3 - Option Verification
43
Introduction
43
Bias Tee Verification, Option 10
44
Low Current Test Verification
44
Bias Tee Verification, Option
44
High Current Test Verification
45
Fault Verification
46
Tracking Generator Verification, Option 20
47
Tracking Generator Verification, Option
47
2-Port Transmission Verification, Option 21
48
2-Port Transmission Verification, Option
48
Power Meter Level Accuracy, Option 29
49
Power Meter Level Accuracy, Option
49
ISDB-T and BER Verification, Options 30 and 79
52
Introduction
52
ISDB-T and BER Verification, Options 30 and
52
Frequency Accuracy Verification
53
Frequency Lock Range Verification
54
Level Accuracy Verification
56
Displayed Average Noise Level (DANL) Verification
59
Phase Noise Verification
59
BER Measurement Functional Check, Option 79 Only
61
GPS Verification, Option 31
63
Frequency Accuracy Verification
63
GPS Verification, Option
63
GPS Antenna Bias Tee Verification
64
ISDB-T SFN Verification, Option 32
65
Introduction
65
ISDB-T SFN Verification, Option
65
Level Accuracy Verification
66
Displayed Average Noise Level (DANL) Verification
70
GSM/GPRS/EDGE Signal Analyzer Verification, Options 40 and 41
71
GSM Signal Analyzer Option Verification
71
GSM/GPRS/EDGE Signal Analyzer Verification, Options 40 and
71
EDGE Burst Power, Frequency Error, and Residual Error Tests
74
CDMA Signal Analyzer Verification, Option 42, 43
76
Cdmaone Channel Power, Frequency Error, Rho, and Tau Verification
76
CDMA Signal Analyzer Verification, Option
76
CDMA2000 Channel Power, Frequency Error, Rho, and Tau Verification
79
Wcdma/Hsdpa Signal Analyzer Verification, Option 44, 45, 65
80
WCDMA Absolute Power Accuracy Verification (Option 44)
80
WCDMA Occupied Bandwidth (OBW) Verification (Option 44)
85
WCDMA RF Channel Power Accuracy (Option 44)
88
HSDPA RF Channel Power Accuracy (Option 44)
89
Equipment Required
91
Anritsu MG3700A Vector Signal Generator
91
Anritsu ML2438A Power Meter
91
Anritsu MA2482D Power Sensor
91
Anritsu 15NN50-1.5C RF Coaxial Cable
91
Aeroflex/Weinschel 1870A Power Splitter
91
Error Vector Magnitude (EVM) Verification (Option 45 or Option 65)
91
Fixed Wimax Signal Analyzer Verification, Option 46, 47
93
Fixed Wimax Signal Analyzer Option Verification (Option 46)
93
Fixed Wimax Signal Analyzer Option Verification (Option 47)
96
TD-SCDMA Signal Analyzer Verification, Option 60, 61
98
3-14 Evdo Signal Analyzer Verification, Option 62, 63 Option 62, Option 63, or both
101
EVDO Signal Analyzer Verification, Option 62, 63
101
8-PSK Modulation Channel Power, Frequency Error, Rho, and Tau Verification
102
QPSK Modulation Channel Power, Frequency Error, Rho, and Tau Verification
103
16-QAM Modulation Channel Power, Frequency Error, Rho, and Tau Verification
104
Idle Slot Channel Power, Frequency Error, Rho and Tau Verification
104
3-15 Dvb-T/H Signal Analyzer Verification, Option 64, 57 Option 64, Option 57, or both
106
DVB-T/H Signal Analyzer Verification, Option 64, 57
106
Frequency Accuracy and Residual MER Verification
106
Frequency Lock Range Verification
108
Equipment Required
108
Anritsu 15NN50-1.5C RF Coaxial Cable
108
Anritsu 2000-1627-R RF Coaxial Cables
108
Anritsu MG3700A Vector Signal Generator
108
Level Accuracy Verification
109
Level Accuracy Verification
112
Displayed Average Noise Level (DANL) Verification
114
BER Measurement Functional Check, Option 57 Only
115
Equipment Required
115
Anritsu 15NN50-1.5C RF Coaxial Cable
115
Anritsu MG3700A Vector Signal Generator
115
DVB-T/H SFN Verification, Option 78
119
Introduction
119
Level Accuracy Verification
119
Displayed Average Noise Level (DANL) Verification
121
3-17 Mobile Wimax Signal Analyzer Verification, Options 66, 67 Option 66, Option 67, or both
122
Mobile Wimax Signal Analyzer Verification, Options 66, 67
122
Mobile Wimax Channel Power Accuracy Tests (Option 66)
122
Mobile Wimax Residual EVM and Frequency Error Tests (Option 67)
126
Spectrum Master
126
Equipment Required
126
10 Mhz Reference Standard
126
Anritsu 15NN50-1.5C RF Coaxial Cable
126
Anritsu 2000-1627-R RF Coaxial Cables
126
Anritsu MG3700A Vector Signal Generator
126
3-18 Lte Signal Analyzer Verification, Options 541 and 542 Option 541, Option 542, or both
129
LTE Signal Analyzer Verification, Options 541 and 542
129
LTE Channel Power Accuracy Tests (Option 541)
130
LTE Frequency Error Tests (Option 542)
132
TD-LTE Signal Analyzer Verification, Options 551 and 552
134
Anritsu MA2482D Power Sensor
134
Anritsu MG3700A Vector Signal Generator
134
Anritsu ML2438A Power Meter
134
Equipment Required
134
TD-LTE Channel Power Accuracy Tests (Option 551)
135
TD-LTE Frequency Error Tests (Option 552)
137
Chapter 4-Battery Information
139
Introduction
139
Battery Pack Removal and Replacement
140
Chapter 5 - Assembly Replacement
143
Introduction
143
Replaceable Parts List
144
Opening the Spectrum Master Case
145
PCB Assembly Replacement
147
SPA Assembly Replacement
149
SPA and MB N Connector Replacement
150
GPS (Option 31) Replacement
151
Motherboard/Spa PCB Assembly Replacement
152
Ethernet PCB Assembly (Option 0411) Replacement
153
Fan Assembly Replacement
155
LCD Assembly Replacement
156
LCD Backlight PCB Removal and Replacement
158
Keypad and Keypad PCB Replacement
159
Touch Screen Replacement
160
Chapter 6-Troubleshooting
161
Introduction
161
Turn-On Problems
161
Other Problems
162
Appendix A-Test Records
165
Test Records for Spectrum Analyzer Verification
166
Frequency Accuracy Verification and Adjustment
166
Single Side Band (SSB) Phase Noise Verification
166
Spurious Response (Second Harmonic Distortion) Verification
166
Resolution Bandwidth Accuracy Verification
167
Spectrum Analyzer Absolute Amplitude Accuracy Verification
169
Residual Spurious Response Verification
175
Displayed Average Noise Level (DANL
176
Third Order Intercept (TOI) Verification
176
Test Records for Options Verification
177
2-Port Transmission Verification, Option 21
177
Bias Tee Verification, Option 10
177
Tracking Generator Verification, Option 20
177
Power Meter Level Accuracy, Option 29
178
ISDB-T and BER Verification, Options 30 and 79
179
GPS Verification, Option 31
184
ISDB-T SFN Verification, Option 32
184
GSM/GPRS/EDGE Signal Analyzer Verification, Options 40 and 41
192
CDMA Signal Analyzer Verification, Option 42, 43
194
WCDMA/HSDPA Signal Analyzer Verification, Option
195
Fixed Wimax Signal Analyzer Verification, Option
197
EVDO Signal Analyzer Verification, Option 62, 63
198
TD-SCDMA Signal Analyzer Verification, Option
198
DVB-T/H Signal Analyzer Verification, Option
200
DVB-T/H SFN Verification, Option 78
206
DVB-T/H SFN Verification, Option 78
207
Mobile Wimax Signal Analyzer Verification, Options
208
LTE Signal Analyzer Verification, Options 541 and 542
211
TD-LTE Signal Analyzer Verification, Options 551 and 552
212
Advertisement
Anritsu Spectrum Master MS2711E User Manual (84 pages)
Spectrum Analyzer
Brand:
Anritsu
| Category:
Measuring Instruments
| Size: 6 MB
Table of Contents
Table of Contents
11
Chapter 1-General Information
15
Introduction
15
Contacting Anritsu
15
Chapter Overview
15
Frequency Range
16
Available Options
16
Standard Accessories
17
Optional Accessories
17
Additional Documents
17
General Description
17
Spectrum Master Specifications
18
Preventive Maintenance
18
Calibration and Verification
18
ESD Caution
19
Battery Replacement
19
Soft Carrying Case
21
Tilt Bail Stand
22
Secure Environment Workplace
23
Spectrum Master Memory Types
23
Erase All User Files in Internal Memory
23
Recommended Usage in a Secure Environment
24
Chapter 2-Instrument Overview
25
Introduction
25
Chapter Overview
25
Turning on the Spectrum Master
25
Front Panel Overview
26
Front Panel Keys
27
Touch Screen Keys
29
Keypad Menu Keys (1 to 9)
29
LED Indicators
30
Display Overview
30
Test Panel Connector Overview
32
Symbols and Indicators
33
Battery Symbols
33
Additional Symbols
34
Data Entry
35
Numeric Values
35
Parameter Setting
35
Text Entry
35
Mode Selector Menu
36
Chapter 3-Quick Start Guide
37
Introduction
37
Measurement Mode Selection
37
Spectrum Analyzer
38
Set the Frequency
38
Set the Measurement Frequency Bandwidth
39
Set the Amplitude
39
Reference Level Offset for External Loss or External Gain
40
Set the Span
40
Single Limit Line
40
Create a Limit Envelope
41
Setting up Markers
42
Select a Measurement Type
43
Chapter 4-File Management
45
Introduction
45
Managing Files
45
Save Files
45
Save Dialog Box
46
Quick Name Keys
46
Recall Files
47
Recall Dialog Box
47
Copying Files
48
Deleting Files
49
Delete Dialog Box
49
File Menu Overview
50
File Menu
51
Save Menu
52
Save Location Menu
53
Save on Event Menu
54
Recall Menu
55
Copy Menu
56
Delete Menu
57
Chapter 5-System Operations
59
System Menu Overview
60
System Menu
61
System Options Menu
62
System Options 2/2 Menu
63
Display Settings Menu
64
Reset Menu
65
Preset Menu
66
Self Test
66
Updating the Spectrum Master Firmware
67
Chapter 6-GPS (Option 31)
69
Introduction
69
Chapter Overview
69
Activating the GPS Feature
69
Saving and Recalling Traces with GPS Information
71
Saving Traces with GPS Information
71
Recalling GPS Information
71
GPS Menu
72
Chapter 7-Master Software Tools
73
Introduction
73
MST Overview
73
Feature Overview
74
Installing MST
77
Connecting to the Instrument
77
Updating Spectrum Master Firmware
77
Appendix A-Measurement Guides
79
Introduction
79
A-1 Introduction
79
Index
81
Advertisement
Related Products
Anritsu Spectrum Master MS2711D
Anritsu MS2711A
Anritsu MS2711
Anritsu Spectrum Master MS2712E
Anritsu MS2717A
Anritsu MS2718B
Anritsu MS2719B
Anritsu MS27100A
Anritsu MS27101A-IBCM
Anritsu MS2717B
Anritsu Categories
Measuring Instruments
Test Equipment
Portable Generator
Control Unit
Thermometer
More Anritsu Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL