Sign In
Upload
Manuals
Brands
Anritsu Manuals
Measuring Instruments
Spectrum Master MS2711D
Anritsu Spectrum Master MS2711D Analyzer Manuals
Manuals and User Guides for Anritsu Spectrum Master MS2711D Analyzer. We have
4
Anritsu Spectrum Master MS2711D Analyzer manuals available for free PDF download: User Manual, Programming Manual, Maintenance Manual
Anritsu Spectrum Master MS2711D User Manual (201 pages)
Spectrum Analysis
Brand:
Anritsu
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
Table of Contents
4
Chapter 1 - General Information
7
Introduction
7
Description
7
Standard Accessories
7
Options
8
Printers
8
Optional Accessories
9
Performance Specifications
12
Preventive Maintenance
16
Calibration
17
Annual Calibration
17
ESD Cautions
17
Anritsu Service Centers
18
Chapter 2 - Quick Start Guide
19
Introduction
19
Turning the MS2711D on for the First Time
19
Front Panel Overview
20
Display Overview
21
Test Panel Connectors
33
Making Spectrum Analyzer Measurements
34
Making a Basic Measurement
40
Example - Measuring a 900 Mhz Signal
40
Save and Recall Display
45
Printing
45
Battery Information
47
Charging a New Battery
47
Charging the Battery in the Instrument
47
Charging the Battery in the Optional Charger
47
Determining Remaining Battery Life
48
Symbols
51
Self Test
52
Error Messages
53
Using the Soft Carrying Case
57
Chapter 3 - Key Functions
58
Introduction
58
Hard Keys
58
Soft Keys
61
Power Meter (Internal)
61
Power Monitor (External Detector) Option 5
65
High Accuracy Power Meter (Option 19)
67
Spectrum Analyzer Menus
69
Transmission Measurement Menus
84
Interference Analyzer Mode (Option 25)
93
Channel Scanner Mode (Option 27)
103
CW Signal Generator Mode (Option 28)
107
All Modes
110
Chapter 4 - Measurement Fundamentals
112
Introduction
112
Measurement Fundamentals
112
Preamplifier
115
Preamplifier Operation
115
Preamplifier Measurement Example
116
Chapter 5 - Field Measurements
131
Introduction
131
Occupied Bandwidth
131
Channel Power Measurement
133
CDMA Channel Power Measurement
133
GSM Channel Power Measurement
135
AMPS Channel Power Measurement
137
Adjacent Channel Power Ratio
139
Adjacent Channel Power Measurement
139
GSM Adjacent Channel Power Measurement
141
AMPS (TDMA) Adjacent Channel Power Measurement
143
Out-Of-Band Spurious Emissions
145
Out-Of-Band Spurious Emission Measurement
145
In-Band/Out-Of-Channel Measurements
147
In-Band Spurious Measurement
147
Field Strength
149
Dynamic Attenuation Control
152
Frequency Converter Interface (Option 6)
153
Bias Tee (Option 10)
153
AM/FM Demodulation
154
Demodulation Procedure
154
Carrier to Interference Ratio Measurement
156
Interference Analysis
159
Noise Marker
160
Chapter 6 - Power Measurements
161
Introduction
161
Making Power Measurements with the Option 29 Power Meter (Internal)
161
Offset Calibration
164
Making Power Measurements with the Option 5 Power Monitor (External)
167
Making Power Measurements with the Option 19 High Accuracy Power Meter6-9
169
Chapter 7 - Transmission Measurement
173
Introduction
173
Measuring Active Devices
173
Calibration
173
Transmission Measurement Procedure
174
Chapter 8 - GPS Feature
176
Introduction
176
Activating the GPS Feature
176
Saving with GPS Information
178
Recalling GPS Information
178
Chapter 9 - Interference Analyzer Mode
180
Introduction
180
Interference Analysis
180
Spectrogram
180
Signal Strength
182
Rssi
183
Signal ID
184
Chapter 10 - Channel Scanner Mode
185
Introduction
185
Channel Scanner
185
Chapter 11 - Signal Generator Mode
188
Introduction
188
Required Equipment
188
Procedure
188
Softkeys
189
Chapter 12 - Handheld Software Tools
190
Introduction
190
Features
190
System Requirements
190
Installation
191
Using Handheld Software Tools
192
Downloading Traces
192
Plot Capture to the PC
193
Plot Upload to the Instrument
193
Plot Properties
193
Index
199
Advertisement
Anritsu Spectrum Master MS2711D Programming Manual (139 pages)
Fast. Accurate, Repeatable, Portable Spectrum Analysis
Brand:
Anritsu
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Table of Contents
4
Programming Overview
7
General Description
7
Cables for the Spectrum Master
7
Serial Communication Parameters
7
Communications Error Checking
7
Parameter Validation
7
Entering Remote Mode
8
Exiting Remote Mode
8
Lifetime of Changes to Spectrum Master Operating Parameters
8
Write Cycle Limitation of Eeprom
8
Documentation Conventions
8
Numeric Representation
8
Bit Positions
8
Control Byte Descriptions
9
Setup System - Control Byte #1 (01H)
9
Select Measurement Mode - Control Byte #3 (03H)
9
Read Time/Date - Control Byte #7 (07H)
10
Set Time/Date - Control Byte #8 (08H)
10
Set Trace Name (Reference Number) - Control Byte #9 (09H)
11
Serial Port Echo On/Off - Control Byte #10 (0Ah)
11
Watch-Dog Timer On/Off - Control Byte #12 (0Ch)
12
Store Sweep Trace - Control Byte #16 (10H)
12
OBSOLETE: Recall Sweep Trace - Control Byte #17 (11H)
12
Save System Setup - Control Byte #18 (12H)
16
Recall System Setup - Control Byte #19 (13H)
17
OBSOLETE: Query System Status - Control Byte #20 (14H)
17
Trigger Self-Test - Control Byte #21 (15H)
22
Read Fail Counter - Control Byte #22 (16H)
22
Clear Fail Counters - Control Byte #23 (17H)
22
Query Trace Names - Control Byte #24 (18H)
23
Delete Sweep Trace - Control Byte #25 (19H)
23
OBSOLETE - Upload SPA Sweep Trace - Control Byte #26 (1Ah)
23
Query Sweep Memory - Control Byte #27 (1Bh)
27
Query System Status - Control Byte #29 (1Dh)
27
Select Printer Type - Control Byte #30 (1Eh)
36
Recall Sweep Trace - Control Byte #33 (21H)
36
OBSOLETE: Set A/B Trace - Control Byte #34 (22H)
47
Set SPA A/B Trace - Control Byte #35 (23H)
47
Upload Spectrum Master Sweep Trace - Control Byte #36 (24H)
48
Get Options - Control Byte #37 (25H)
57
Query Power Level - Control Byte #39 (27H)
57
Set Power Meter Units - Control Byte #40 (28H)
58
Power Meter Relative Mode On/Off - Control Byte #41 (29H)
58
Power Meter Offset Mode On/Off - Control Byte #42 (2Ah)
58
Power Meter Zero Mode On/Off - Control Byte #43 (2Bh)
59
Power Meter RMS Averaging On/Off - Control Byte #44 (2Ch)
59
Power Meter Center Frequency and Span Setup - Control Byte #45 (2Dh)
60
Sweep Data Echo On/Off - Control Byte #49 (31H)
60
Check Battery Status - Control Byte #50 (32H)
61
Set SPA Minimum Sweep Time - Control Byte #53 (35H)
62
Yte )
62
Ontrol Byte #55 (37 H )
62
Setup - Control Byte #64 (40 Ontrol Byte #65 (41 H )
63
Yte #66 (42 H )
73
Ontrol Byte #67 (43 H )
83
Byte #68 (44 H )
90
Byte #69 (45 H )
91
Mmediately - Control Byte #70 (46 H )
91
Ontrol Byte #71 (47 H )
92
Control Byte #72 (48 H )
92
Yte #82 (52 H )
93
Yte )
94
Yte )
95
Yte )
96
Ratio (Acpr) - Control Bower (Acpr) - Control Byte #88 (58 Ontrol Byte #89 (59 H )
97
Yte #91 (5B H )
97
Control Byte #96 (60 H )
98
Control Byte #97 (61 H )
99
Ontrol Byte #98 (62 H )
99
Byte #99 (63 H )
100
Cale - Control Byte #101 (65 H )
101
Arker - Control Byte #102 (66 H )
101
Yte #106 (6A H )
102
Control Byte #145
103
Ontrol Byte #107 (6B H )
103
H )
104
Byte #111 (6F H )
104
Nalyzer Sweep Time - Control Byte - Control Byte #115 (73 H )
106
105
106
Mpedance - Control Byte #116 (74 Byte #117 (75 H )
108
Ontrol Byte #118 (76 H )
108
Yte )
109
Tatus - Control Byte #131 (83 H )
109
Byte #134 (86 H )
109
External Reference - Control Ff /Auto ) - Control Byte #136 (88 Nits - Control Byte #140 (8C H )
110
Byte #141 (8D H )
111
H )
111
Yte #197 (C5 H )
112
D0 H )
113
Ontrol Byte #221 (DD H )
113
Yte #198 (C6 H )
113
Control Byte #225 (E1 H )
114
GPS Power - Control Byte #237 (Edh)
114
Read GPS Position - Control Byte #238 (Eeh)
114
Automatic Cal Disable - Control Byte #240 (F1H)
115
Recall Sweep Trace - Control Byte #243 (F3H)
115
Exit Remote Mode - Control Byte #255 (Ffh)
115
Select Spa/Power Meter Signal Standard - Control Word (A103H)
116
Select Spa/Power Meter Channel - Control Word (A104H)
116
Read External Module Name - Control Word (A201H)
116
Read External Module Serial Number - Control Word (A202H)
117
Read External Module Frequency Range - Control Word (A203H)
117
Clear Module Fail Counter - Control Word (A205H)
118
Perform Transmission Mode Calibration - Control Word (A301H)
118
Turn off Transmission Mode Calibration - Control Word (A302H)
118
Get Signal Standard Name - Control Word (A501H)
119
Perform Noise Diode Cal - Control Word (A505H)
119
Set Bias T Voltage - Control Word (A506H)
119
Select Function in IA Measurement Mode - Control Word (A700H)
119
Spectrogram: Set Sweep Interval - Control Word (A721H)
120
Spectrogram: Set Time Span of Measurement - Control Word (A722H)
120
Spectrogram: Turn On/Off Auto Save - Control Word (A723H)
120
Spectrogram: Get Trace Name - Control Word (A724H)
121
Spectrogram: Recall Trace - Control Word (A725H)
122
Set Frequency in CW GENERATOR MODE - CODE WORD(A801H)
122
Retrieve Power in CW GENERATOR MODE - CODE WORD(A802H)
123
Remote Self Test - Control Word (Aa15H)
123
Trigger Sweep - Control Word (Aa30H)
125
Parameter Definitions
126
Programming Examples
127
Examples in C
127
Example in Visual Basic
134
Revision History
136
Anritsu Spectrum Master MS2711D Programming Manual (116 pages)
Fast. Accurate, Repeatable, Portable Spectrum Analysis
Brand:
Anritsu
| Category:
Analytical Instruments
| Size: 0 MB
Table of Contents
Table of Contents
3
Programming Overview
6
Control Byte Summary
8
Control Byte Descriptions
12
Setup System - Control Byte #1 (01H)
12
Select Measurement Mode - Control Byte #3 (03H)
12
Read Time/Date - Control Byte #7 (07H)
12
Set Time/Date - Control Byte #8 (08H)
13
Set Reference Number - Control Byte #9 (09H)
13
Serial Port Echo On/Off - Control Byte #10 (0Ah)
13
Watch-Dog Timer On/Off - Control Byte #12 (0Ch)
14
Store Sweep Trace - Control Byte #16 (10H)
14
Recall Sweep Trace - Control Byte #17 (11H)
15
Save System Setup - Control Byte #18 (12H)
19
Recall System Setup - Control Byte #19 (13H)
19
Query System Status - Control Byte #20 (14H)
20
Trigger Self-Test - Control Byte #21 (15H)
24
Read Fail Counter - Control Byte #22 (16H)
24
Clear Fail Counters - Control Byte #23 (17H)
25
Query Trace Names - Control Byte #24 (18H)
25
Delete Sweep Trace - Control Byte #25 (19H)
25
Upload SPA Sweep Trace - Control Byte #26 (1Ah)
25
Query Sweep Memory - Control Byte #27 (1Bh)
29
Query System Status - Control Byte #29 (1Dh)
29
Select Printer Type - Control Byte #30 (1Eh)
36
Recall Sweep Trace - Control Byte #33 (21H)
37
Set A/B Trace - Control Byte #34 (22H)
44
Set Spectrum Analyzer A/B Trace - Control Byte #35 (23H)
44
Upload Sweep Trace - Control Byte #36 (24H)
45
Get Options - Control Byte #37 (25H)
50
Query Power Level - Control Byte #39 (27H) (Option 29 Only)
50
Set Power Meter Units - Control Byte #40 (28H) (Option 29 Only)
51
Power Meter Relative Mode On/Off - Control Byte #41 (29H) (Option 29 Only)
51
Power Meter Offset Mode On/Off - Control Byte #42 (2Ah) (Option 29 Only)
51
Power Meter Zero Mode On/Off - Control Byte #43 (2Bh) (Option 29 Only)
51
Power Meter RMS Averaging On/Off - Control Byte #44 (2Ch) (Option 29 Only)
52
Power Meter Center Freq and Span Setup - Control Byte #45 (2Dh) (Option 29 Only)
52
Trigger Sweep - Control Byte #48 (30H)
52
Sweep Data Echo On/Off - Control Byte #49 (31H)
53
Check Battery Status - Control Byte #50 (32H)
53
Set SPA Minimum Sweep Time - Control Byte #53 (35H)
54
Set Trigger Position - Control Byte #54 (36H)
54
Set Video Trigger Level - Control Byte #55 (37H)
54
Automatically Save Runtime Setup - Control Byte #64 (40H)
55
Download Saved Setup - Control Byte #65 (41H)
55
Upload Setup - Control Byte #66 (42H)
65
Query Saved Setups - Control Byte #68 (44H)
75
Enter Remote Mode - Control Byte #69 (45H)
76
Enter Remote Mode Immediately - Control Byte #70 (46H)
76
Write Protect Setup - Control Byte #71 (47H)
77
Clear Setup Memory Location - Control Byte #72 (48H)
77
Write Antenna - Control Byte #82 (52H)
78
Recall Antenna - Control Byte #83 (53H)
78
Set Field Strength Measurement - Control Byte #84 (54H)
79
Set Channel Power - Control Byte #85 (55H)
79
Read Channel Power - Control Byte #86 (56H)
80
Set Adjacent Channel Power Ratio (ACPR) - Control Byte #87 (57H)
80
Read Adjacent Channel Power Ratio (ACPR) - Control Byte #88 (58H)
81
Read Signal Standard Name - Control Byte #89 (59H)
81
Measure OCC BW % of Power - Control Byte #96 (60H)
81
Measure OCC BW Db down - Control Byte #97 (61H)
82
Set Bias Tee Function - Control Byte #98 (62H) (Option 10 Only)
82
Set Spectrum Analyzer Start/Stop Frequency - Control Byte #99 (63H)
83
Set Spectrum Analyzer Center Freq./Span - Control Byte #100 (64H)
83
Set Spectrum Analyzer Scale - Control Byte #101 (65H)
83
Set Spectrum Analyzer Marker - Control Byte #102 (66H)
84
Set Spectrum Analyzer Single Limit - Control Byte #103 (67H)
84
Set Spectrum Analyzer Peak Hold - Control Byte #105 (69H)
85
Set Spectrum Analyzer Resolution Bandwidth - Control Byte #106 (6Ah)
85
Set Spectrum Analyzer Video Bandwidth - Control Byte #107 (6Bh)
85
Set Spectrum Analyzer Sweep Mode - Control Byte #108 (6Ch)
86
Set Spectrum Analyzer Marker to Peak - Control Byte #109 (6Dh)
86
Set Spectrum Analyzer Marker to Center - Control Byte #110 (6Eh)
86
Set Spectrum Analyzer Attenuation - Control Byte #111 (6Fh)
86
Set Spectrum Analyzer Multiple Limit - Control Byte #113 (71H)
87
Set Return Spectrum Analyzer Sweep Time - Control Byte #114 (72H)
88
Set Reference Level Offset - Control Byte #115 (73H)
88
Set Spectrum Analyzer Impedance - Control Byte #116 (74H)
89
Read Marker Value - Control Byte #117 (75H)
89
Set Sweep Averaging - Control Byte #118 (76H)
90
Normalize Spectrum Analyzer - Control Byte #130 (82H)
90
Set Spectrum Analyzer Normalization Status - Control Byte #131 (83H)
90
Set / Reset Spectrum Analyzer External Reference - Control Byte #133 (85H)
90
Check Spectrum Analyzer External Reference - Control Byte #134 (86H)
91
Set Spectrum Analyzer Preamp State (On/Off/Auto) - Control Byte #136 (88H)
91
Set Spectrum Analyzer Units - Control Byte #140 (8Ch)
91
Set Spectrum Analyzer Resolution Bandwidth - Control Byte #141 (8Dh)
92
Set Spectrum Analyzer Video Bandwidth - Control Byte #142 (8Eh)
92
Set Spectrum Analyzer Attenuation - Control Byte #143 (8Fh)
93
Set AM/FM Demodulation - Control Byte #145 (91H)
93
Set Baud Rate - Control Byte #197 (C5H)
94
Set Language - Control Byte #198 (C6H)
94
Query Time - Control Byte #208 (D0H)
94
Read ASCII Serial Number - Control Byte #225 (E1H)
95
Exit Remote Mode - Control Byte #255 (Ffh)
95
Select Spectrum Analyzer/Power Meter Signal Standard - Control Word (A103H)
95
Select Spectrum Analyzer/Power Meter Channel - Control Word (A104H)
95
Read External Module Name - Control Word (A201H) (Option 6 Only)
96
Read External Module Serial Number - Control Word (A202H) (Option 6 Only)
96
Read External Module Frequency Range - Control Word (A203H) (Option 6 Only)
96
Read Module Fail Counter - Control Word (A204H) (Option 6 Only)
97
Clear Module Fail Counter - Control Word (A205H) (Option 6 Only)
97
Perform Transmission Mode Calibration - Control Word (A301H) (Option 21 Only)
97
Turn off Transmission Mode Calibration - Control Word (A302H) (Option 21 Only)
98
Remote Self Test - Control Word (Aa15H)
98
Trigger Sweep - Control Word (Aa30H)
100
Programming Examples
101
Examples in C
101
Example in Visual Basic
110
Parameter Definitions
112
Spectrum Analyzer Signal Standards
113
Advertisement
Anritsu Spectrum Master MS2711D Maintenance Manual (48 pages)
Brand:
Anritsu
| Category:
Measuring Instruments
| Size: 0 MB
Table of Contents
Table of Contents
3
Introduction
5
Description
5
Spectrum Analyzer Frequency Accuracy
5
Spectrum Analyzer Phase Noise Verification
6
Spectrum Analyzer Second Harmonic Distortion Test
7
Spectrum Analyzer Residual Spurious Response Test
8
Spectrum Analyzer Resolution Bandwidth Accuracy Test
10
Spectrum Analyzer Measurement Accuracy Verification
13
Power Monitor Verification (Option 5)
21
Bias Tee (Option 10) Verification
23
Bias Tee Verification (Option 10A)
23
Transmission Measurement Verification (Option 21)
25
Power Meter Verification (Option 29)
27
FCN4760 Frequency Converter Verification
29
Battery Pack Removal and Replacement
35
Battery Information
37
Front Panel Assembly Removal and Replacement
38
LCD Assembly Replacement
40
Key Pad PCB Replacement
41
Key Pad Membrane Replacement
42
Main PCB Assembly Replacement
42
Option 5 Power Monitor PCB Assembly Replacement
44
Accessories and Replaceable Parts
45
Customer Service
47
Advertisement
Related Products
Anritsu Spectrum Master MS2711E
Anritsu MS2711A
Anritsu MS2711
Anritsu Spectrum Master MS2712E
Anritsu Spectrum Master MS2713E
Anritsu MS2717A
Anritsu MS2717B
Anritsu MS2718B
Anritsu MS2719B
Anritsu MS27101A-IBCM
Anritsu Categories
Measuring Instruments
Test Equipment
Portable Generator
Control Unit
Thermometer
More Anritsu Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL