CD-S500 Series
Slashed Zero
It sets whether or not slash is used with the numeral 0 (ZERO).
Initial value: OFF
Print Direct.
Designates the printing direction. When BIDIR is selected, printing starts from the left or right ends
of the next printing line which is closer to the location where the previous print has stopped.
When UNI-DIR is selected, printing always starts from the left end.
Initial value: BI-DIR
Auto LF
The LF operation at the time of "CR" is selected. When it is OFF, only CR is operated. When it is
ON, both CR and LF are operated.
Initial value: OFF
Code Page
The code page is selected. Types of code page: 437/850/860/863/865/852/866/857/858/WPC
Initial value: 437
Buffer Size
The receiving buffer size is selected from 40 or 4K bytes.
Initial value: 4 K
Init Signal
Selects either "enabled" (ENB) or "disabled" (DIS) of the printer initializing signal (PRIME) when a
Centronics interface is used.
Selects either "enabled" (ENB) or "disabled" (DIS) of the 25 pin reset signal when a serial interface
is used.
Initial value: ENB
Buzzer
Selects either "enabled" (ON) or "disabled" (OFF) of the buzzer sound when an abnormality occurs.
Initial value: ON