config lldp message_tx_hold_multiplier

Purpose
Syntax
Description
Parameters
Restrictions
Example usage:
To configure LLDP Message tx hold multiplier settings:
DES-1210-28/ME:5# config lldp message_tx_hold_multiplier 2
Command: config lldp message_tx_hold_multiplier 2
Success!
DES-1210-28/ME:5#

config lldp reinit_delay

Purpose
Syntax
Description
Parameters
Restrictions
Example usage:
To configure LLDP reinit delay:
DES-1210-28/ME:5# config lldp reinit_delay 1
Command: config lldp reinit_delay 1
Success!
DES-1210-28/ME:5#
DES-1210-28/ME Metro Ethernet Managed Switch CLI Reference Guide
DES-1210-28/ME:5# config lldp message_tx_interval 10
Command: config lldp message_tx_interval 10
Success!
DES-1210-28/ME:5#
To define the lldp hold-multiplier on the switch.
config lldp message_tx_hold_multiplier <int 2-10>
The config lldp message_tx_hold_multiplier command specifies
the amount of time the receiving device should hold a Link Layer
Discovery Protocol (LLDP) packet before discarding it.
Message_tx_hold_multiplier (int 2-10) – Specifies the hold time to
be sent in the LLDP update packets as a multiple of the timer value.
(Range: 2-10). The default configuration is 4.
Only Administrator or operator-level users can issue this command.
To define the lldp reinint–delay on the switch.
config lldp reinit_delay <sec 1-10>
The lldp reinit_delay seconds command specifies the minimum
time an LLDP port will wait before reinitializing LLDP transmission.
<sec 1-10> – Specifies the minimum time in seconds an LLDP port
will wait before reinitializing LLDP transmission. The range is 1 – 10
seconds. The default configuration is 2 seconds.
Only Administrator or operator–level users can issue this command.