Reading Parameters
Good Read Beep Length (continued)
$CBPLE14
Good Read Beep Length = 200 msec

Illumination Control

Controls illumination during a good read beep.
NOTE
DEFAULT
$CBPIC01
Illumination Control = Illumination and beep are
independently controlled
Product Reference Guide
Setting this configuration item to turn off illumination during the beep
reduces the peak current drawn by the reader in some scanning modes.
Enter/Exit Programming Mode
$CBPLE12
Good Read Beep Length = 180 msec
$CBPIC00
$
Illumination Control = Illumination off during beep