Symbologies

Datalogic 2 of 5 Check Character Transmission

This option enables/disables transmission of an optional Datalogic 2 of 5 char-
acter.
DEFAULT
$CD2CT01
Datalogic 2 of 5 Check Character Transmission = Send

Datalogic 2 of 5 Minimum Reads

This feature specifies the minimum number of consecutive times an Datalogic 2
of 5 label must be decoded before it is accepted as good read.
$CD2MR02
Datalogic 2 of 5 Minimum Reads = 2
$CD2MR04
Datalogic 2 of 5 Minimum Reads = 4
Product Reference Guide
Enter/Exit Programming Mode
$CD2CT00
Datalogic 2 of 5 Check Character Transmission = Don't Send
$CD2MR01
Datalogic 2 of 5 Minimum Reads = 1
DEFAULT
$CD2MR03
Datalogic 2 of 5 Minimum Reads = 3