System Options For Transfer - NEC SL100 Programming Manual

Digital
Table of Contents

Advertisement

SL1000
Level
IN
Description
Use Program 24-02 : System Options for Transfer to define the system options for the Transfer fea-
Program
ture.
24
Input Data
Item
No.
01
Busy Transfer
Use this option to prevent or allow extensions
to Transfer calls to busy extensions. If dis-
abled, calls transferred to busy extensions re-
call immediately.
02
MOH or Ringback on Transferred Calls
Use this option to enable or disable MOH on
Transfer. If enabled (0), a transferred caller
hears MOH while their call rings the destina-
tion extension. If disabled (1), a transferred
caller hears ringback while their call rings the
destination extension.
03
Delayed Call Forwarding Time
If activated at an extension, Delayed Call For-
warding occurs after this time. This also sets
how long a Transferred call waits at an exten-
sion forwarded to Voice Mail before routing to
the called extension mailbox.
04
Transfer Recall Time
An unanswered transferred call recalls to the
extension that initially transferred it after this
time.
05
Message Wait Ring Interval Time
For Single Line Telephones (SLTs) without
message waiting lamps, this is the time be-
tween intermittent ringing. If this value is set to
0, the system rings once.
07
Trunk-to-Trunk Transfer Release Warning
Tone
Time starts when a trunk begins talking with
another trunk (for example : trunk-to-trunk
transfer, outgoing from trunk, Tandem Trunk-
ing). When this time expires, a warning tone is
heard. If Program 24-02-10 is set, the conver-
sation disconnects after time expires. This
time is set again when the external digit timer
expires. One of the trunks used must be an
analog trunk (or leased line).
08
Delayed Transfer Time for all Department
Groups
09
Two B-Channel Transfer Retry Timer
10
Disconnect Trunk-to-Trunk
11
No Answer Step Transfer
2-264
Program 24 : Hold/Transfer Setup

24-02 : System Options for Transfer

Item
0 = Disable (No)
1 = Enable (Yes)
0 = Hold Tone
1 = Ring Back Tone
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 30 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
Input Data
Default
0
0
10 seconds
30 seconds
30 seconds
1800 seconds
10 seconds
10 seconds
0
10 seconds
Program 24 : Hold/Transfer Setup
ISSUE 1.1
Related Pro-
gram
20-03-02
20-31-15
20-31-16
14-01-25
20-28-01
20-28-02
20-28-03
24-02-10
11-11-28
11-11-29
15-07-59
10-03-16
(PRI)
14-01-25
20-28-01
20-28-02
20-28-03
24-02-07
14-01-26

Hide quick links: