NEC SL100 Programming Manual page 31

Digital
Table of Contents

Advertisement

ISSUE 1.1
Item No.
04
Line Length Selection
05
T1 Clock Source
06
Number of Ports
For E1 PKG Setup
Physical Port Number
Item No.
01
Logical Port Number
02
Number of channels
04
E1 Clock Source
05
Transmit Pulse Mask
06
Frame Type
07
Line Coding
10
Receive Input Threshold
For VoIPDB PKG Setup
Physical Port Number
Item No.
01
Trunk Logical Port Number
02
Trunk Type
Conditions
• When changing a defined terminal type, first set the type to 0 and then plug the new device in to
have the system automatically define it, or redefine the type manually.
• The system must have a unit installed to view/change the options for that type of unit.
Programming Manual
Item
0 = 0 feet ~ 133 feet
1 = 133 feet ~ 266 feet
2 = 266 feet ~ 399 feet
3 = 399 feet ~ 533 feet
4 = 533 feet ~ 655 feet
0 = Internal
1 = External
0 = Auto
1 = 4 Ports
2 = 8 Ports
3 = 12 Ports
4 = 16 Ports
5 = 20 Ports
Item
1 ~ 126
0 ~ 30
0 = Internal
1 = External
0 = 01 to 133 feet
1 = 133 to 266 feet
2 = 266 to 399 feet
3 = 399 to 533 feet
4 = 533 to 655 feet
0 = Double Frame (no CRC-4)
1 = Multiframe Structure (CRC-4)
0 = AMI
1 = HDB3
0 = 0.91/1.70 V
1 = 0.74/0.84 V
2 = 0.59/0.84 V
3 = 0.42/0.45 V
4 = 0.32/0.45 V
5 = 0.21/0.20 V
6 = 0.16/0.10 V
7 = 0.10/not defined
Item
1 ~ 126
0 = H.323
1 = SIP
Input Data
01 ~ 30
Input Data
01 ~ 16
Input Data
SL1000
Default
0
1
0
Program
10
Default
0
0
1
0
0
1
2
Default
0
1
2-9

Hide quick links:

Advertisement

Table of Contents
loading