Program
Use Program 10-12 : CPU Network Setup to setup the IP Address, Subnet-Mask, and Default Gate-
way addresses.
10
Caution! If any IP Address or NIC settings are changed, the system must be reset for the
changes to take affect.
Input Data
Item
Item
No.
01
IP Address
02
Subnet Mask
03
Default
Gateway
04
Time Zone
2-16
Program 10 : System Configuration Setup
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.255.255.254
192.0.0.1 ~ 223.255.255.254
128.0.0.0
240.0.0.0
254.0.0.0
255.192.0.0
255.248.0.0
255.255.0.0
255.255.224.0
255.255.252.0
255.255.255.128
255.255.255.240
255.255.255.254
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.255.255.254
192.0.0.1 ~ 223.255.255.254
0~24 (0 = -12 Hours and 24 = +12 Hours)

10-12 : CPU Network Setup

Input Data
192.0.0.0
224.0.0.0
248.0.0.0
252.0.0.0
255.0.0.0
255.128.0.0
255.224.0.0
255.240.0.0
255.252.0.0
255.254.0.0
255.255.128.0
255.255.192.0
255.255.240.0
255.255.248.0
255.255.254.0
255.255.255.0
255.255.255.192
255.255.255.224
255.255.255.248
255.255.255.252
255.255.255.255
Program 10 : System Configuration Setup
ISSUE 1.1
Default
Description
192.168.0.10
Set for CPU.
255.255.255.0 The setting of
Subnet Mask
is invalid when
all Host Ad-
dresses are 0.
If the network
section is:
0,
127,
128.0,
191.255,
192.0.0,
223.255.255
The setting of
Subnet Mask
is invalid.
0.0.0.0
IP Address for
Router.
12
Determine the
offset from
Greenwich
Mean Time
(GMT) time.
Then enter its
respective
value.
For example,
Eastern Time
(US and
Canada) has a
GMT offset of
-5.
The program
data would
then be 7
(0 = - 12,
1 = - 11,
2 = - 10,
3 = - 9,
4 = - 8,
5 = - 7,
6 = - 6,
7 = - 5,
:
24 = + 12)