Technical data
Taurus 355 TDM
Technical data
8
Performance specifications and guarantee only in connection with original spare and
replacement parts!
8.1
Taurus 355 TDM
Setting range for welding current
Setting range for welding voltage
Duty cycle
60%
100%
Load alternation
Open circuit voltage
Mains voltage (tolerances)
Frequency
Mains fuse
(safety fuse, slow-blow)
Mains connection lead
Max. connected load
Recommended generator rating
cos
Insulation class/protection
classification
Ambient temperature
Machine/torch cooling
Workpiece lead
Dimensions (L x W x H)
Weight
EMC class
Constructed to standards
56
NOTE
MIG/MAG
5 A–350 A
14,3 V - 31,5 V
40 °C
350 A
300 A
10 min. (60% DC
6 min. welding, 4 min. pause)
79 V
3 x 400 V (-25% to +20%)
50/60 Hz
3 x 25 A
H07RN-F4G4
13,9 kVA
20,2 kVA
0.99
H/IP 23
-25 C to +40 C
Fan/gas
70 mm
625 mm x 300 mm x 535 mm
41 kg
A
IEC 60974 -1, -10
/
MMA
20,2 V - 34,0 V
15,0 kVA
2
099-005221-EW501
16.04.2014
Need help?
Do you have a question about the Taurus 355 Basic TDM and is the answer not in the manual?
Questions and answers