8.2

Taurus 405 TDM

Setting range for welding current
Setting range for welding voltage
Duty cycle
100%
Load alternation
Open circuit voltage
Mains voltage (tolerances)
Frequency
Mains fuse
(safety fuse, slow-blow)
Mains connection lead
Max. connected load
Recommended generator rating
cos
Insulation class/protection
classification
Ambient temperature
Machine/torch cooling
Workpiece lead
Dimensions (L x W x H)
Weight
EMC class
Constructed to standards
099-005221-EW501
16.04.2014
MIG/MAG
5 A–400 A
14.3 V–34.0 V
40 °C
400 A
10 min. (60% DC
6 min. welding, 4 min. pause)
79 V
3 x 400 V (-25% to +20%)
50/60 Hz
3 x 35 A
H07RN-F4G4
17.2 kVA
24.6 kVA
0.99
H/IP 23
-25 C to +40 C
Fan/gas
70 mm
625 mm x 300 mm x 535 mm
41 kg
A
IEC 60974 -1, -10
/
Technical data
Taurus 405 TDM
MMA
20.2 V–36.0 V
18.2 kVA
2
57