3.1.4 Setting the System Time Clock

This programming sequence sets the internal time clock in the 1816 system. (Note – if you only want
to set the time, you can stop after step 4).
Factory Default = (Not Programmed)
1. Take the doorman telephone off hook.
2. Press *33 and enter the four-digit MASTER CODE _ _ _ _ (beep).
3. Enter the hour and minutes (HHMM) _ _ _ _ then press * (beep).
4. Enter 0 for AM; or enter 1 for PM _ then press * (beep).
5. Enter the month, day and year (MMDDYY) _ _ _ _ _ _ then press * (beep).
6. Enter the day of the week (1=Sunday, 7=Saturday) _ then press *(beep).
7. Hang up the doorman telephone to end the programming session.

3.1.5 Set the Caller ID Number

The system will provide a Caller ID to the resident phone when a call is generated from either the entry
panel or the doorman/concierge phone. This is necessary because some telephones equipped with
caller ID functions will not work unless a phone number is displayed. The caller ID number may be set
to anything, it has no other function.
Factory Default = 1234567890
1. Take the doorman telephone off hook.
2. Press *41 and enter the four-digit MASTER CODE _ _ _ _ (beep).
3. Enter the 10-digit caller ID number _ _ _ _ then press * (beep).
4. Hang up the doorman telephone to end the programming session.

3.1.6 Set the Talk Time

Talk time is the length of time that the 1816 system will allow communication to take place before
disconnecting. Talk time is set using a three digit code to set the time in seconds. Talk time can be
set from 001 to 255 seconds.
NOTE: When a DoorKing lobby panel is connected to the system, talk time should be set to 255
seconds. The lobby panel talk time should be set to the desired time and will override the talk
time set here. Refer to the lobby panel programming instructions to set the lobby panel talk
time.
Factory Default = 060
1. Take the doorman telephone off hook.
2. Press *08 and enter the four-digit MASTER CODE _ _ _ _ (beep).
3. Enter the three-digit talk time in seconds (001 – 255) _ _ _ then press * (beep).
4. Hang up the doorman telephone to end the programming session.