2.2 Wiring Detail – Large Main Cabinet
1816 Telephone Intercom System
Wiring Detail - Large Control Cabinet
1 2 3 4
5
6
7 8 9 10
7
Lobby Panel
Doorman Telephone
4
1 2
3
4
5
1816-065-L-11-14
1 2 3 4
5
6
7 8 9 10
11 12
13
6
6
16 Volt, 40 VA UL Listed Transformer.
1
Earth Ground.
2
Optional Central Office phone line - touch tone, loop start.
3
Doorman Telephone (Optional).
4
Lobby panel. Connect additional lobby panels in parallel. Refer to lobby panel installation manual for additional
5
wiring requirements.
Use twisted pair wires for phone connections. 24 AWG up to 800 feet; 22 AWG up to 1600 feet.
6
Decoder board wiring, 18 AWG. Wire necessary decoder boards corresponding
7
terminals to corresponding terminals.
INCOMING
C.O. PHN
9
8
11
RJ71 phone block P/N 2370-010. See drawing M1816-065-6 for detail.
8
Incoming phone lines from Central Office.
9
Outgoing phone lines to individual apartments.
10
DoorKing connecting cable.
11
14
15
16
17
18
19
20
21
22
23 24
2
16 VAC
C.O.
PWR
INPUT
PHN
1
3
Title:
Date:
Resident
Telephone
LINES
10
DOORKING, INC., INGLEWOOD, CA 90301
1816 Telephone Intercom System
Wiring Detail
11/14
Dwg. No.
M1816-065-5