Main Garden Style Cabinet - DKS 1816 Owner's Manual

Telephone intercom system
Hide thumbs Also See for 1816:
Table of Contents

Advertisement

2.1 Wiring Detail – Garden Style Cabinet
1816 Telephone Intercom System
Wiring Detail - Garden Style Control Cabinet
Lobby Panel
4
1 2
3
4
5
1
2
3
4
5
6
7
8
9
10
11
Page 20
7
11 12
13
14
6
Doorman Telephone
6
16 Volt, 40 VA UL Listed Transformer.
Earth Ground.
Optional Central Office phone line - touch tone, loop start.
Doorman Telephone (Optional).
Lobby panel. Connect additional lobby panels in parallel. Refer to lobby panel installation manual for additional
wiring requirements.
Use twisted pair wires for phone connections. 24 AWG up to 800 feet; 22 AWG up to 1600 feet.
Decoder board terminals. Use only if more than 5 relay boards are connected
to system. See drawing M1816-065-5.
RJ71 phone block P/N 2370-010. See drawing M1816-065-6 for detail.
Incoming phone lines from Central Office.
Outgoing phone lines to individual apartments.
DoorKing connecting cable.
9
8
11
15
16
17
18
19
20
21
22
23 24
2
16 VAC
C.O.
PWR
PHN
INPUT
1
3
Title:
Date:
INCOMING
C.O. PHN
LINES
Resident
Telephone
10
DOORKING, INC., INGLEWOOD, CA 90301
Main / Garden Style Cabinet
Board Layout
C
11/14
Dwg. No.
M1816-065-4
Rev.
1816-065-L-11-14

Advertisement

Table of Contents
loading

Table of Contents