2.3.6 Talk Time

Factory setting is 060 (60 Seconds).
This programming sequence sets the maximum time allowed for conversation when the 1812 places a call to the resident's
house, or if call forwarding is active, or if any of the dial out numbers are used. Talk time can be set from 10 seconds up to
255 seconds (4 minutes, 15 seconds) and is entered as a three-digit number. For example, to set a talk time of 30 seconds,
enter 030 in step 2.
1. Press
2. Enter the talk time code (010-255), then press
3. Press 0 # TOGETHER to end. [0 # (beeeeeep)]

2.3.7 Relay Strike Time

Factory setting for Relays 1 and 2 is 01 (1 Second).
These steps will program the system relay strike times.
Relay strike times can be programmed from 1/4 second - enter 0 0
System relays 1 and 2 are the two relays on the 1812 main circuit board.
1. Press
2. Enter a relay number (1 or 2), then press
3. Enter the two-digit strike time (00-99), then press
4. Repeat steps 2 and 3 to set the other relay strike time if necessary.
5. Press 0 # TOGETHER to end. [0 # (beeeeeep)]

2.3.8 Tone Open Numbers

Factory setting is 9876 for Relay 1; 5432 for Relay 2.
These steps will program the tone open number(s) for each relay in the system (each relay is programmed independently).
You will need to enter a four-digit number (see chart below) to set each relay in step 3. If a function is not desired, enter #
in place of the digit. Use a different number for each of the four-digits in step 3 when multiple functions are desired.
Note: "Hold Open" and "Hold 1 hour" will not function when a call is made via dialing a directory number.
Example 1: If you want the relay to have a "momentary activation" function only, and you want it to activate when the
number 9 is pressed, enter 9 # # #
Example 2: If you only want the relay to hold open when the number 8 is pressed and the relay deactivated when the
number 7 is pressed, enter # 8 7 #
1. Press
2. Enter a relay number (1 or 2), then press
3. Choose and enter a four-digit tone open number code (see chart below), then press
4. Repeat steps 2 and 3 to set the other relay tone open number(s) if desired.
5. Press 0 # TOGETHER to end. [0 # (beeeeeep)]
4 Digit Tone Open Number Code
1st Digit (Step 3)
2nd Digit (Step 3)
3rd Digit (Step 3)
4th Digit (Step 3)
24
0 8 and enter the MASTER CODE. [
*
0 3 and enter the MASTER CODE. [
*
in step 3.
*
in step 3.
*
0 5 and enter the MASTER CODE. [
*
[ _ _ _ _
(beep)]
*
If a tone open function is not desired, enter # in place of a number.
Momentary activation. Relay will activate for its programmed relay strike time.
Hold open (latch). Relay will activate and remain activated until commanded to deactivate.
Deactivate relay.
Hold open 1 hour. Relay will activate for 1 hour and then deactivate itself.
0 8 _ _ _ _ (beep)]
*
. [ _ _
(beep)]
*
*
in step 3, up to 99 seconds - enter 9 9
*
0 3 _ _ _ _ (beep)]
*
. [ _
(beep)]
*
*
. [ _ _
(beep)]
*
*
0 5 _ _ _ _ (beep)]
*
. [ _
(beep)]
*
*
Function
in step 3.
*
.
*
1812-161-L-12-11

Hide quick links: