Resolving Errors Upon Startup
If an error occurs during booting, the LED light of Soft Keys 1 through 4
will remain on to indicate an error status. These errors represent hardware
failures within the IP Phone.
• LED 1 light on = memory check failed
• LED 2 light on = network failed
• LED 3 light on = DHCP failed
• LED 4 light on = attached IP address failed
If the phone successfully passes through these stages, it has started up
properly. Otherwise, refer to "Troubleshooting" on page 35.
Active Logon While Another Handset is Already
Logged On To the Same Extension
If another analog phone or IP phone is already logged on to the same
extension, rebooting the Alti-IP 600 will not register the phone
successfully. The user must press #26 on the associated physical phone/IP
phone, then on the IP phone, use #27 + ENTER to actively log onto
AltiServ. Once the extension is logged on and activated, the calls will then
be redirected to this IP Phone.
Important:
Also, the user should not use the VM option to logon the
Alti-IP 600.
Restoring Default Settings
To automatically restore the original default settings for the Alti-IP 600:
1.
Press * * 7, then press the ENTER button
2.
Press * * 2, then press the ENTER button.
Rebooting the Alti-IP 600
To reboot the Alti-IP 600, press * * 3, then press the ENTER button.
Note: When the Alti-IP 600 is rebooted, the AltiWare IP address setting
is set back to the original configuration.
Alti-IP 600 Administration Manual 17
Need help?
Do you have a question about the Alti-IP 600 and is the answer not in the manual?