Option 39: Siren Timeout; Option 40: Trouble Beeps; Option 41: Chime Voice - GE Euro Simon Installation Instructions Manual

Table of Contents

Advertisement

Note
This option must be on for
Option 52: Unvacated Pre-
mises and Option 59: Exit
Extension to work correctly.
Euro Simon Security System
When this option is on, the panel announces all open/failed sensors repeatedly for 4 minutes, then
automatically bypasses the open sensors and arms the rest of the system. If a sensor is opened
during the exit delay and then left open, the panel will go into alarm after the exit delay has
expired.
Pressing the ARM Doors & Windows button a second time (before the 4-minute time expires)
bypasses all open sensors and arms the rest of the system. Pressing this button a third time elimi-
nates the entry delay.
¾
To turn on Auto Arm, press:
Add—Option #—38—DONE.
When this option is off, the panel announces all open/failed sensors once, then automatically
bypasses the open sensors and arms the rest of the system after the Exit Delay has expired. If
other sensors are opened during the exit delay, they will also be bypassed if left open.
¾
To turn off Auto Arm, press:
Delete—Option #—38—DONE.
Option 39: Siren Timeout (Default = 4 min.)
Determines how long sirens sound alarms if no one is present to disarm the system.
The time can be set from 002 - 254 minutes. Entries must be 3 digits. When this feature is turned
off, sirens sound alarms until the alarm is canceled (system is disarmed).
¾
To set Siren Timeout, press:
Add—Option #—39—002 - 254—DONE.
¾
To turn off Siren Timeout, press:
Delete—Option #—39—DONE.
Option 40: Trouble Beeps (Default = on)
Determines whether the panel, X-10, and hardwire interior sirens sound six beeps every minute
when a trouble condition occurs (on) or not (off). The following conditions cause trouble beeps:
AC power failure
Low CPU battery
Sensor failure (supervisory)
Sensor trouble (low battery)
Fail to communicate
No Activity timer has timed out. Trouble beeps continue for 5 minutes and if the panel does
not see activity, trouble beeps stop and the panel reports the no activity to the central station.
Trouble beeps can be silenced by arming or disarming the system, or by pressing the STATUS
button. Trouble beeps resume 4 hours later if the trouble condition is not cleared.
¾
To turn on Trouble Beeps, press:
Add—Option #—40—DONE.
¾
To turn off Trouble Beeps, press:
Delete—Option #—40—DONE.
Option 41: Chime Voice (Default = off)
Determines whether the panel announces the sensor number and name (on) or only sounds beeps
(off), when the CHIME Doors or CHIME Special Motion features are on and sensors in groups
10, 13, and 25 are tripped while the system is disarmed.
¾
To turn on Chime Voice, press:
Add—Option #—41—DONE.
¾
To turn off Chime Voice, press:
Delete—Option #—41—DONE.