Appendix A:
Troubleshooting
Euro Simon Security System

System Status

How to clear SYSTEM STATUS (Alarm Memory)
From a disarmed state press SYSTEM STATUS, listen to the status message, then press DIS-
ARM.
Panel announces Siren 1 failure or Siren 2 failure.
Turn option 53 off if a hardwire siren or sensor is not connected.
Check for the correct end-of-line resistor in HWIN 1 and 2 circuits.
Panel announces Low Battery.
Check that panel backup battery is connected.
Panel announces Option 50 Detected.
Option 50 is RF jam detect. The control panel has detected RF interference.
Panel announces that a sensor is open.
See Sensors section below.
Panel announces System time is not set.
Set the system time.

Control Panel

Panel announces Function not available when Chime Doors is pressed.
No sensors are programmed using sensor type 10 or 13.
Panel announces Function not available when Chime Special Motion is pressed.
No sensors are programmed using sensor type 25.
Panel announces Function not available when LIGHTS Time Activated is pressed.
No time activated lights have been programmed.
Panel announces Function not available when LIGHTS Sensor Activated is pressed.
No sensor activated lights have been programmed.
Panel announces Invalid. Sensor already programmed as Sensor Name.
This sensor is already programmed. Delete sensor if not correctly programmed.

Options (Programmable by the homeowner)

Panel does not beep.
Turn on (add) Option 1.
Latchkey does not function.
Latchkey time (option 3) is not set. Set Latchkey time.
Latchkey is not enabled. Enable Latchkey by pressing ARM Motion Sensors twice.
The phone number is not programmed properly. Reprogram the phone number. (options 13 or
43)
System Time is not set. Set system time.

Sensors

A sensor does not work.
Make sure the battery is fresh and installed correctly.
Check for interference from metal objects. Move or rotate the sensor.
Move the sensor to a new location.
Door or window is closed, but the panel announces it is open.
Be certain the arrow on the magnet and the guide line on the transmitter are aligned and
within 1/4 inch of each other.
The sensor tamper switch may be open (cover off).
42