This option must be on for
Option 52 and 59: Unva-
cated Premises and Exit
Extension to work correctly.
Note
For UL Listed systems, this
option must be on.
Note
For UL listed systems, Siren
Timeout must be set to at
least 4 minutes.
Note
For UL listed systems, Trou-
ble Beeps must be on.
Simon Security System
Note
The panel protests an arming attempt when it has not received a restore (close) signal from
sensors learned into restore-specific sensor groups. Sensors learned into group 26 (Fire)
cannot be bypassed. See "Sensor Group Characteristics" in "Appendix B" to identify sensor
groups with restore signal requirements.
When this option is on, the panel announces all open/failed sensors repeatedly for 4
minutes, then automatically bypasses the open sensors and arms the rest of the system.
If a sensor is opened during the exit delay and then left open, the panel will go into
alarm after the exit delay has expired.
Pressing the ARM Doors & Windows button a second time (before the 4-minute time
expires) bypasses all open sensors and arms the rest of the system. Pressing this button
a third time eliminates the entry delay.
¾ To turn on Auto Arm, press:
Add—Option #—38—DONE.
When this option is off, the panel announces all open/failed sensors once, then auto-
matically bypasses the open sensors and arms the rest of the system after the Exit
Delay has expired. If other sensors are opened during the exit delay, they will also be
bypassed if left open.
¾ To turn off Auto Arm, press:
Delete—Option #—38—DONE.
Option 39: Siren Timeout (Default = 4 min.)
Determines how long sirens sound alarms if no one is present to disarm the system.
The time can be set from 002 - 254 minutes. Entries must be 3 digits. When this fea-
ture is turned off, sirens sound alarms until the alarm is canceled (system is disarmed).
¾ To set Siren Timeout, press:
Add—Option #—39—002 - 254—DONE.
¾ To turn off Siren Timeout, press:
Delete—Option #—39—DONE.
Option 40: Trouble Beeps (Default = on)
Determines whether the panel, X10, and hardwire interior sirens sound six beeps every
minute when a trouble condition occurs (on) or not (off). The following conditions
cause trouble beeps:
AC power failure
Low CPU battery
Sensor failure (supervisory)
Sensor trouble (i.e. low battery, tamper, etc.)
Fail to communicate
No Activity timer has timed out. Trouble beeps continue for 5 minutes and if the
panel does not see activity, trouble beeps stop and the panel reports the no activity
to the central station.
Trouble beeps can be silenced by arming or disarming the system, or by pressing the
STATUS button. Trouble beeps resume 4 hours later if the trouble condition is not
cleared.
¾ To turn on Trouble Beeps, press:
Add—Option #—40—DONE.
¾ To turn off Trouble Beeps, press:
Delete—Option #—40—DONE.
30