07 Portable Auxiliary: 24 hour portable auxiliary button. Siren shut off confirms
CS report
08 Special Intrusion: such as gun cabinets and wall safes.
09 Special Intrusion: such as gun cabinets and wall safes.
10 Entry/Exit Delay: Entry/Exit Delay that require a standard delay time. Chime
13 Instant perimeter: Exterior doors and windows. Chime
14 Instant Interior: Interior doors
15 Instant Interior: Interior PIR motion sensors
16 Instant Interior: Interior doors
17 Instant Interior: PIR motion sensors
18 Instant Interior Cross Zone: PIR motion sensors
19 Delayed Interior: interior doors that initiate a delay before going into alarm
20 Delayed Interior: PIR motion sensors that initiate a delay before going into
alarm
21 Local Instant Interior: 24 hour local alarm zone protecting anything that
opens and closes. No Report.
22 Local delayed interior: same as group 21, plus activation initiates a delay
before going into alarm. No report.
23 Local instant Auxiliary: 24 hour local alarm zone protecting anything that
opens and closes. No report
24 Local Instant Auxiliary: 24 hour local alarm zone protecting anything that
opens and closes. Sirens shut off at restoral. No report.
25 Local Special Chime: Notify the user when a door is opened. Sounds emit
from a local annunciator. Direct Bypass and Unbypass when no Special
Motion Chime sensors are in the security system. No report.
26 Fire: 24 hour fire, rate-of-rise heat, and smoke sensors§.
27 Lamp control or other customer feature. No report
28 PIR motion sensor, sound sensor, or pressure mat. No report
29 Auxiliary: Freeze Sensors
32 PIR motion sensor or sound sensor. No report
34 Carbon Monoxide Alarm
35 Entry/Exit Delay Interior PIR Motion
36 Special Intrusion: such as gun cabinets and wall safes. Reports as a tamper
if tripped
37 Light Switch Control: X-10 Modules turn either on or off when a door is
opened. No report.
38 Auxiliary: Water Sensors.
Delays:
I = Instant Delay (no delay, immediate alarm)
S = Standard Delay (alarm sounds after programmed entry delay time)
F = Follower Delay (alarm sounds immediately if entry/exit delay is not active, otherwise alarm sounds after programmed
entry delay time)
45
Sensor Group Characteristics
Name/Application
Siren Type
Emergency
I
No
No
Intrusion
I
Yes Yes
Intrusion
S
Yes Yes
Intrusion
S
Yes Yes
Intrusion
I
Yes Yes
Intrusion
F
Yes Yes
Intrusion
F
No
Yes
Intrusion
F
Yes Yes
Intrusion
F
No
Yes
Intrusion
F
No
Yes
Intrusion
S
Yes Yes
Intrusion
S
No
Yes
Intrusion
I
Yes Yes
Intrusion
S
Yes Yes
Emergency
I
Yes Yes
Emergency
I
Yes Yes
Three Beeps
I
No
Yes
Fire
I
Yes Yes
Silent
I
Yes Yes
Silent
I
No
Yes
Trouble
I
Yes Yes
Beeps
Silent
I
No
No
Emergency
I
Yes Yes
Intrusion
S
No
Yes
Intrusion
I
Yes Yes
Silent
I
No
Yes
Trouble
I
Yes Yes
Beeps
Euro Simon Security System
Active
in
Levels
01234
1234
1234
24
24
234
234
34
34
34
34
34
1234
1234
01234
01234
01234
01234
01234
01234
01234
01234
01234
234
1234
01234
01234