Pressing DONE is required if
you enter fewer than 26 dig-
its. The phone number is
automatically stored without
pressing DONE if all 26
places are used.
Note
This option is typically used
only in Europe where a
supervisory condition is
required to report as a
tamper.
Euro Simon Security System
¾
To change Access Code Length, press:
Add—Option #—54—3, 4, 5, or 6—DONE.
¾
To reset Access Code Length (to default), press:
Delete—Option #—54—DONE.
Option 55: Status Beep Volume (Default = 07)
Determines the panel piezo volume level for status sounds such as arming, trouble, and status
beeps.
The volume can be set from 1 (lowest) to 10 (highest). Turning off this option resets the volume
to the default setting. Entries must be 2 digits.
¾
To set Status Beep Volume, press:
Add—Option #—55—01 - 10—DONE.
¾
To reset Status Beep Volume (return to default), press:
Delete—Option #—55—DONE.
Option 56: Call Waiting (Default = off)
Lets you program up to a 26-digit number or code that disables call waiting or any other phone
service before dialing central station or voice event notification phone numbers (on). When this
option is turned off, the panel dials only the central station phone number.
Press Test for each required pause, Add for a *, and Delete for a # (each of which uses one of the
26 available places).
¾
To program Call Waiting, press:
Add—Option #—56—Up to 26 digits—DONE.
¾
To delete Call Waiting, press:
Delete—Option #—56—DONE.
Option 57: Supervisory/Tamper Report (Default = off)
Determines whether the panel sends supervisory reports to a central station as a tamper (on) or a
supervisory (off).
¾
To report supervisories as Tamper Reports, press:
Add—Option #—57—DONE.
¾
To report supervisories as Supervisory Reports, press:
Delete—Option #—57—DONE.
Access Code Length Defaults
Setting
Default Code
3
Master—123
Utility 1—321
Utility 2—321
4
Master—1234
Utility 1—4321
Utility 2—4321
5
Master—12345
Utility 1—54321
Utility 2—54321
6
Master—123456
Utility 1—654321
Utility 2—654321
30