Note
System time must be set
correctly for this feature to
work.
Note
System time must be set
correctly for this feature to
work.
Note
System time must be set
correctly for this feature to
work.
Note
Both Options 36 and 37
must have a time pro-
grammed for this feature to
work correctly.
Note
System time must be set
correctly for this feature to
work.
Note
Both Options 36 and 37
must have a time pro-
grammed for this feature to
work correctly.
25
Option 34: Fail to Open Report (Default = off)
Determines whether the panel sends a Fail to Open report to a central station if the system has
not been disarmed by the programmed time (on), or not (off).
¾
To turn on Fail to Open Report, press:
Add—Option #—34—Hours—Minutes—DONE.
¾
To turn off Fail to Open Report, press:
Delete—Option #—34—DONE.
Option 35: Fail to Close Report (Default = off)
Determines whether the panel sends a Fail to Close report to a central station if the system has
not been armed by the programmed time (on), or not (off).
¾
To turn on Fail to Close Report, press:
Add—Option #—35—Hours—Minutes—DONE.
¾
To turn off Fail to Close Report, press:
Delete—Option #—35—DONE.
Option 36: Sensor Activated Light Lockout Start Time (Default = off)
Sets the START time that determines when the panel prevents the sensor activated lights fea-
ture from turning on sensor activated lights.
When a time value is set (on) and the sensor activated lights feature is on, the panel prevents
sensor activated lights from turning on between the programmed start time (this option) and
the programmed stop time (Option 37).
When both Options 36 and 37 are turned off and the sensor activated lights feature is on, sen-
sor activated lights turn on at all times.
¾
To set Sensor Activated Light Lockout Start Time, press:
Add—Option #—36—Hours—Minutes—DONE.
¾
To turn off Sensor Activated Light Lockout Start Time, press:
Delete—Option #—36—DONE.
Option 37: Sensor Activated Light Lockout Stop Time (Default = off)
Sets the STOP time that determines when the panel prevents the sensor activated lights feature
from turning on sensor activated lights.
When a time value is set (on) and the sensor activated lights feature is on, the panel prevents
sensor activated lights from turning on between the programmed start time (Option 36) and the
programmed stop time (this option).
When both Options 36 and 37 are turned off and the sensor activated lights feature is on, sen-
sor activated lights turn on at all times.
¾
To set Sensor Activated Light Lockout Stop Time, press:
Add—Option #—37—Hours—Minutes—DONE.
¾
To turn off Sensor Activated Light Lockout Stop Time, press:
Delete—Option #—37—DONE.
Option 38: Auto Arm (Default = off)
Determines how long the system protests (announces open/failed sensors) when attempting to
arm with open/failed sensors, before bypassing these sensors and automatically arming the rest
of the system.
Note
The panel protests an arming attempt when it has not received a restore (close) signal from sensors
learned into restore-specific sensor groups. Sensors learned into group 26 (Fire) cannot be
bypassed. See "Sensor Group Characteristics" in "Appendix B" to identify sensor groups with restore
signal requirements.