To close your XMC-1 back up for use after testing or changing the internal fuses, do the following:
While your XMC-1 is still in an upright position, put the shielding enclosure back in its proper
position and replace the four screws securing it to the XMC-1 front panel. Remember that the
shielding enclosure mounts under the lip on the inside of the front panel, and that the screws
go through the front panel lip and thread into the metal of the shielding enclosure.
Note: When you replace the screws, you will not be doing so in the exact reverse of the order in
which they were removed. By replacing the four top screws first, you will find it easier to align
the two screws on the bottom.
Note: All six screws securing the shielding enclosure are the same size.
Note: Be careful to avoid pulling any cables when positioning the shielding enclosure, or
pinching any cables between the enclosure and the chassis when tightening the screws.
Stand the XMC-1 on its side and replace the two screws securing the shielding enclosure to
the chassis of the XMC-1 from the bottom. You may have to push the edge of the shielding
enclosure into position and hold it in place while inserting the screws.
Replace the top panel of the XMC-1, and replace the eight screws securing it.
Replace the power cable.
It's a good idea to confirm that your XMC-1 is now working before replacing it in your
equipment rack and reconnecting it.
Fuse Values
All fuses are 20mm x 5mm 250 V time delay type: T250
The main AC power fuse is a T250 3.15A (250 V / 3.15 amps)
F1 on the power supply board is a T250 250mA (250 V / 250 mA)
F2 on the power supply board is a T250 4A (250 V / 4 amps)
Care and Maintenance
Page 84