3
Submenu Advanced Settings
18
bintec User's Guide
Field
GPRS/UMTS Interface
Channel Bundling
Total Number of Chan-
nels
Description
Only for L
1 P
AYER
ROTOCOL
Defines the slot for the UMTS modem card.
Possible values:
Slot 0 Unix 8 AUX (default value): Defines
slot 0 for use with a modem.
Slot 6 Unit 0 UMTS: Defines slot 6 for use
with an UMTS modem card.
Defines whether and which type of channel
bundling is to be used for ISDN connections to
the WAN partner.
Possible values:
no (default value): No channel bundling,
only one B-channel is ever available for
connections.
static: Static channel bundling.
dynamic: Dynamic channel bundling.
The field is not displayed when L
P
= PPP over Ethernet (PPPoE), PPP
ROTOCOL
over PPTP.
For dynamic channel bundling: Defines the
maximum number of B-channels that may be
opened.
For static channel bundling: Defines the num-
ber of B channels that are open throughout the
connection.
The default value is 1.
= GPRS/UMTS.