Toshiba Tl000LE User Manual page 29

Table of Contents

Advertisement

PROCEDURE 2
Test Program Check
The HDD test program is stored in the TlOOOLE Diagnostics Disk. Perform all HDD tests.
Detailed operation is described in Part 3.
If an error is detected during the HDD test, an error code and status will be displayed; perform
PROCEDURE 3. The err0r code and status are described in Table 2-3. If no error is
generated, the HDD is normal.
Table 2-3 HDD error code and status
Code
Status
Olh
Bad command error
02h
Bad address mark
04h
Record not found
I
OSh
HDC not reset
07h
Drive not initialize
09h
DMA boundary error
OAh
Bad sector error
OBh
Bad track error
lOh
ECC error
llh
ECC recover enable
20h
HDC error
40h
Seek error
SOh
Time out error
AAh
Drive not ready
BBh
Undefined
CCh
Write fault
EEh
Access time out· error
EOh
Status error
FOh
Not sense error (HW. code=FF)
2-23