Two-camera Unit

2-7

Two-camera Unit

Note If the V530-R150 and the Two-camera Unit are not turned ON
Power
Supply
System Configuration
24 VDC
F150-VS Camera
Cable (3 m)
Two different
Cameras can
be connected.
Note Turn OFF the power to all of the system devices before connect-
26
When the F150-A20 Two-camera Unit is used, two cameras can be
connected to a single V530-R150 and images can be received at the
same time.
simultaneously, be sure to turn ON the Two-camera Unit first.
Images might not be received properly if the V530-R150 is turned
ON first.
Connect a 24-VDC power supply. The Two-camera Unit requires the
same kind of crimp connectors and wire as the V530-R150's power
supply connection.
F150-A20 Two-
camera Unit
Camera with a Light Source:
F150-SL20A or F150-SL50A
Camera with an Intelligent Light Source:
F150-SLC20 or F150-SLC50
Camera Only:
F150-S1A
ing or disconnecting cables. Connecting or disconnecting cables
with power turned ON can damage the devices.
F150-VA
Camera Unit
Cable (15 cm,
included with
the Two-cam-
era Unit)
Section 2-7