Trigger Input and Output Format
DO0 to DO3 Terminals
Note The initial status of the output terminals is OFF. The terminals,
36
OK: ON or NG: ON (i.e.: whether output turns ON for an OK judgment
or an NG judgment) can be selected in the communications specifi-
cations settings.
The default setting is NG: ON. “ page 199
While the coincidence judgment function is ON, the signals are as fol-
lows:
How to set coincidence judgment function “ page 145
Coincident with registered data 0: DO0 terminal turns ON.
Coincident with registered data 1: DO1 terminal turns ON.
Coincident with registered data 2: DO2 terminal turns ON.
Coincident with registered data 3: DO3 terminal turns ON.
however, may turn ON for approximately 0.5 s when the power is
turned ON. Be sure to allow for this when connecting to an exter-
nal device.