forcibly switch the Programmable Controller to MONITOR
mode.
The 3964(R) procedure controls data transmission via a point-to-
point connection between a Siemens product and a communications
partner.
1.
The character delay time defines the maximum amount of time
permitted between two incoming characters within a message
frame.
Select 20 ms to 655350 ms in 10-ms increments.
The shortest character delay time depends on the baud rate.
1200 bits/s
2400 to 76800 bits/s
(Default setting: 220 ms)
2.
The acknowledgment delay time defines the maximum amount of
time permitted for the partner's acknowledgment to arrive during
connection setup (time between STX and partner's DLE acknowl-
edgment) or release (time between DLE ETX and partner's DLE
acknowledgment).
Select 20 ms to 655350 ms in 10-ms increments.
The shortest acknowledgment delay time (ADT) depends on the
baud rate.
1200 bits/s
2400 to 76800 bits/s
(Default setting: 2000 ms)
Cha. delay time
:
[ 22]x10ms
Ack. delay time
:
[ 200]x10ms
Setup att. count
:
[ 6]
trans. att. count
:
[ 6]