Trigger Inputs and Output Format
Write Light Level Settings (@LW)
Send
@ L W
@ L W
<Camera no.>
Receive
Changes the light level settings for the specified Camera's Intelligent
Light.
The command format depends on the Intelligent Light Source that is
being used. There are 5 settings in the F150-SLC20 Intelligent Light
Source and 8 settings in the F150-SLC50 Intelligent Light Source.
F150-SLC20 Specified
<Camera no.>
Set the camera no. to 0 or 1 and set the light level for each area. The
light level settings for areas A to E can range from 0 to 7; a value of 0
is OFF and 7 is the maximum brightness.
F150-SLC50 Specified
(A) (B)
Set the camera no. to 0 or 1 and set the light level for each area. The
light level settings for areas A to H can range from 0 to 7; a value of 0
is OFF and 7 is the maximum brightness.
"OK" indicates that the command was executed correctly:
<Header>
"ER" indicates that the command was not executed correctly:
<Header>
(A) (B)
(C) (D)
(C) (D)
(E)
(F) (G) (H)
O K <Footer>
E R <Footer>
Section 4-3
1:1 Connection
(E)
<Footer>
Viewed from this
this direction
<Footer>
Viewed from this
this direction
79