SET (Setting) Mode
0. Image Adjust
Note When the shutter speed is 1/10000s, the brightness of the light
Light Control 0 (or 1)
When a Camera with an Intelligent Light Source is connected, the
light level can be adjusted from the V530-R150.
Light Control 0 is the lighting for Camera 0 and Light Control 1 is the
lighting for Camera 1. Change the settings in the SYS/Device set-
tings menu in advance to indicate that an Intelligent Light Source is
being used. “ page 210
might not change even when the light level is adjusted. Synchro-
nize pulse flashes from the Intelligent Light Source with the shut-
ter speed and adjust the pulse width to control the light level.
When the shutter speed is 1/2000s, the light pulse width is 450 ms
and the light level can be adjusted to a maximum value of 7.
When the shutter speed is at the fastest 1/10000s setting, the light
pulse width is 130 ms so the light level can be adjusted up to 2. Any
settings higher than 2 are ineffective. (The light level will not change
with higher settings.)
1/10000s light
emission period
1/10000s shutter
period
Light level: 7 (about 450 µs max.)
Light level: 2
(about
130 µs)
Light level
Light level cannot
can be ad-
be adjusted.
justed.
Section 6-1