Omron V530-R150E-3 Operation Manual page 109

2-dimensional code reader (fixed type)
Hide thumbs Also See for V530-R150E-3:
Table of Contents

Advertisement

Connection Examples
Communication Settings
Program Examples
1,2,3...
92
• V530-R150 Settings “ page 194 and page 196
Communication setting
Host Link setting
• Programmable Controller Settings
Item
Communications mode
1 : 1 / 1: N
Unit No.
Baud rate
Data length
Parity bits
Stop bits
This program inputs a One Shot Reading Command to the Program-
mable Controller's DM. The V530-R150 references this command
and reads the data. The reading data is written to the specified words
in the Programmable Controller.
1.
Set the reading conditions of the V530-R150 and set the reading
mode to RUN mode.
2.
Set the Start Reading Command in DM0100 of the Programma-
ble Controller.
“ The V530-R150 reads codes, sets the Write Flags in DM0110,
and writes the reading data to DM words beginning with DM0111.
Item
Baud rate
Data length
Parity bits
Stop bits
Mode
Read area
Begin read word
Write area
Begin write word
SYSWAY (Host Link)
1 : N
00
Match the settings with a V530-R150
Section 4-5
Setting
The same settings as
those of the Program-
mable Controller.
Host link
DM
0100
DM
0110
Setting