Installation - Intermec EasyCoder 601 XP Service Manual

Bar code label printer
Hide thumbs Also See for EasyCoder 601 XP:
Table of Contents

Advertisement

12.2 Installation

Ribbon Low Sensor
NOTE!
The Ribbon Unwind Unit
does not need to be dismounted!
Intermec EasyCoder 601 XP – Service Manual Ed. 2
• Open the right-hand door.
• Turn off the power and remove the left-hand cover.
• From the paper compartment side, insert the connector and cable
through the square hole in the centre-line wall.
• Insert the sensor under the code disk of the ribbon unwind unit
so the disc will run in the U-shaped slot between the receiver and
transmitter. There is no need to dismount the ribbon unwind unit.
• Attach the sensor to the centre-line wall by means of one #T10
Torx screw. Check that the code disc can rotate freely.
• Connect the cable to P57 on the CPU board, see chapter 15.3.
• Put back the left-hand cover.
• Turn on the power and check that the sensor works by reading
its values using a PRINT SYSVAR(13) instruction in Intermec
Fingerprint while manually rotating the ribbon unwind spool.
Chapter 12
Ribbon Low Sensor
#T10 Torx Screw
82