16.4 Industrial Interface
Board,
cont'd.
Intermec EasyCoder 601 XP – Service Manual Ed. 2
Industrial Interface Configuration
The Industrial Interface provides:
• 8 digital IN ports with opto-couplers (Opto In)
• 8 digital OUT ports with opto-couplers (Opto Out)
• 4 OUT ports with relays (Relay Out)
The Industrial Interface has no straps or circuits to be fitted or
removed. All signals are available on a female DB44 connector and
the various ports are controlled by the Intermec Fingerprint instruc-
tions PORTIN and PORTOUT ON/OFF (see Intermec Fingerprint
7.12 Reference Manual).
Digital Opto In
The status of the digital IN ports 101–108 can be read by means of
PORTIN functions. If a current is led through the opto-coupler of
the port, PORTIN returns the value -1 (true), else the value 0 (false).
Signal
Description
Vin [High]
Input Voltage High
Vin [Low]
Input Voltage Low
Connector Configuration
Pin
Signal Name Description
10
IN1A
Anode Opto In Channel 1 +
40
IN1K
Cathode Opto In Channel 1 -
26
IN2A
Anode Opto In Channel 2 +
11
IN2K
Cathode Opto In Channel 2 -
41
IN3A
Anode Opto In Channel 3 +
27
IN3K
Cathode Opto In Channel 3 -
12
IN4A
Anode Opto In Channel 4 +
42
IN4K
Cathode Opto In Channel 4 -
28
IN5A
Anode Opto In Channel 5 +
13
IN5K
Cathode Opto In Channel 5 -
43
IN6A
Anode Opto In Channel 6 +
29
IN6K
Cathode Opto In Channel 6 -
14
IN7A
Anode Opto In Channel 7 +
44
IN7K
Cathode Opto In Channel 7 -
30
IN8A
Anode Opto In Channel 8 +
15
IN8K
Cathode Opto In Channel 8 -
VCC
R17
IC8D
8
9
74HC14
Simplified schematics of a digital IN port.
Chapter 16
Min,
10V
-1V
TIL193B
R25
IC16D
7
10
9
C27
8
GND
Interfaces
Typical
Max.
24V
40V
0V
1V
Fingerprint Ref. No.
101
102
103
104
105
106
107
108
P4
R33
10
IN1A
40
IN1K
121
Need help?
Do you have a question about the EasyCoder 601 XP and is the answer not in the manual?