3.13.2 Pump Assembly Removal

1. Remove the cap assembly. (Refer to Section 3.13.1.)
2. Remove 2 screws (CBS, 3x6, F/Zn) securing the outer sub frame assembly to the middle
sub frame assembly and to the slider shaft respectively. Then remove the whole outer sub
frame assembly with the pump drive gear and the pump reduction gear. (Refer to Figure 3-
41.)
Rev. A
Download Service Manual and Resetter Printer at http://printer1.blogspot.com
Figure 3-41. Outer Sub Frame Assembly Removal